SMC Networks KFG2H-E Series Скачать руководство пользователя страница 8

- 8 - 

 

2. Specific Product Precautions (4)

 

 
 

(6)Take note that if nylon tubing, soft nylon tubing 

and antistatic tubing are used in a clean room. 

The  antioxidant  on  the  surface  of  the  soft  nylon 
tubing  may  come  off,  thereby  lowering  the 
cleanness level.

 

(7)Do  not  use  in  environments  where  foreign 

matter may stick to the product or get mixed in 
the product's interior. 

This  may  cause  leakage  or  disconnection  of  the 
tubing.

 

 
 
 

 
 

       

   

Warning

 

(1) Perform maintenance inspections according to 

the  procedures  indicated  in  the  operation 
manual. 

If handled improperly, malfunction and damage of 
machinery of equipment may occur. 

(2) Maintenance work

 

If  handled  improperly,  compressed  air  can  be 
dangerous.  The  assembly,  handling,  repair,  and 
element  replacement  of  pneumatic  systems 
should  be  performed  by  a  knowledgeable  and 
experienced person. 

(3) Drain flushing 

Remove drainage from air filters regularly.

 

(4)  Removal  of  equipment  and  supply/exhaust  of 

compressed air

 

When components are removed, first confirm that 
measures are in place to prevent workpieces from 
dropping,  run-away  equipment,  etc.  Then,  cut  off 
the  supply  pressure  and  electric  power,  and 
exhaust all compressed air from the system using 
the residual pressure release function. 
When  the  equipment  is  restarted,  proceed  with 
caution 

after 

confirming 

that 

appropriate 

measures  are  in  place  to  prevent  cylinders  from 
sudden movement. 

     

 

Caution

 

(1)  Be  certain  to  wear  safety  glasses  at  all  times 

during periodical inspections.   

(2)  During  regular  maintenance,  check  for  the 

following  and  replace  any  components  as 
necessary. 

a) Scratches, gouges, abrasion, corrosion 
b) Leakage 

   

c) Flattening or distortion of tubing 
d) Hardening, deterioration or softness of tubing 
e) Loosening of the union nut 

(3) Do not repair the fittings or patch the tubing for 

reuse. 

 
 
 
 
 
 

 
(4) After operation at a high temperature, leakage 

may  occur  due  to  time  dependent  change  of 
the  tube  material.  If  leakage  occurs,  remove 
the tube, cut off the connecting part of the tube, 
and connect to the piping again. 

Check if the tube dimension accuracy is within the 
recommended tolerance. If it is difficult to take the 
tube out of the body, bend the tube to the side to 
remove. 

 

 

 
 

 

 
 

         

Caution 

(1)  First,  tighten  the  fitting  by  hand,  then  use  a 

wrench appropriate for the hexagon flats of the 
body to tighten it.For a tightening torque guide, 
see the table below.

 

If  the  fitting  is  tightened  with  excessive  torque,  it 
may break. 

 

Connection thread size

 

Tightening torque [N

m]

 

M5 

1 to 1.5 

G1/8 

3 to 5 

G1/4 

8 to 12 

G3/8 

15 to 20 

G1/2 

20 to 25 

 

(2)  Insufficient  tightening  may  cause  seal  failure, 

or loosen the threads. 

 
 
 

 

     

Caution 

(1)  When  using  the  KFG2H*-E  series  with  tubing 

other  than  those  from  SMC,  the  products  are 
not subject to warranty.

 

 

Connection Thread Tightening Method 

 

Maintenance

 

Tube 

Body 

Precautions for use with non-SMC

 

 

Operating Environment

 

2021-03-30 17:38

DP105573

Содержание KFG2H-E Series

Страница 1: ...Doc No KF OM00002 PRODUCT NAME EHEDG Compliant Fittings MODEL Series Product Number KFG2H E series...

Страница 2: ...2 Contents 1 Safety Instructions 3 4 2 Specific Product Precautions 5 8 3 Specifications 9 4 Troubleshooting 9 5 Construction 9...

Страница 3: ...tion to any possibility of equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsa...

Страница 4: ...replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product 3 Prior...

Страница 5: ...ndrel diameter mm Twice against the minimum bending radius Test temperature 20 5o C Relative humidity 65 5 3 Do not use fluids other than listed on the specifications Applicable fluids are air and wat...

Страница 6: ...ollapse or deformation of the hexagonal face or damage to the equipment After installing confirm that there is no damage to the fitting etc 7 Use a tool with soft internal surface such as plastic to p...

Страница 7: ...oils including organic solvents salt or corrosive gases etc as it can cause damage or malfunction Caution 1 Install an air filter Install an air filter at the upstream side of valve Select an air fil...

Страница 8: ...sures are in place to prevent cylinders from sudden movement Caution 1 Be certain to wear safety glasses at all times during periodical inspections 2 During regular maintenance check for the following...

Страница 9: ...Material Remarks 1 Union nut Stainless steel 316 NSF H1 grease 2 Gasket FDA compliant FKM 3 Body Stainless steel 316 4 Gasket FDA compliant FKM Stainless steel Metal exists in nature as ore like oxid...

Страница 10: ...ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufactu...

Отзывы: