-19-
No. JXC
※
-OMY0008
4. Initial Setting
4.1 Switch setting (EtherCAT ID)
Set the EtherCAT ID to “000 - 999” using the combination of rotary switches.
The EtherCAT ID of the controller is set using the rotary switches.
Also, the EtherCAT ID can be set by the EtherCAT master device regardless of the switch
combination.
To set the EtherCAT ID through the EtherCAT master device, refer to the manual of the EtherCAT
master device.
Caution
When the EtherCAT ID is set by the EtherCAT master device, the setting by the switch will be invalid.
When using the switch setting as EtherCAT ID again, please be sure to set the value to "0" by the
EtherCAT master device before using.
ECAT ID
Setting
EtherCAT ID
x100
x10
x1
0
0
0
Value that setting by
EtherCAT master device
0
0
1
1
0
0
2
2 (Factory default)
0
:
:
:
0
6
4
64
:
:
:
:
9
9
9
999
Caution
Turn OFF the power supply while setting the switch.
The rotary switch should be set with a small watchmaker’s screwdriver.
4.2 Hardware Configuration
■
ESI file (XML file)
ESI file (XML file) is required to configure the controller.
ESI file (XML file) can be downloaded from the URL given below.
Informative documents
→
Operation manual -->SMC JXCEH_V10.zip
•Contents of SMC JXCEH_V10.zip
ESI file:
SMC JXCEH_V10.xml
EtherCAT
スレーブ
ID
:
1
~
999(
工場出荷時
1)
EtherCAT ID: 0
~
999 (Factory default “002”)
Содержание JXCEH