-7-
JXC
※
-OMX0018
2.2 How to order
Order number of the controller
J X C D 1 7 T - L E Y 2 5 E A - 1 0 0
Communication protocol
Order number of the controller
Option
Mounting
7
Direct mounting
8 *
DIN rail mounting
* DIN rail is not included.
It must be ordered separately.
Nil*
N/A
S
With straight communication plug
T
With T branch communication plug
* For products other than JXCD1, select Nil.
E
EtherCAT®
9
EtherNet/IP
TM
P
PROFINET
D
DeviceNet
TM
L
IO-Link
(Enter from the actuator product number "LE" to
"stroke")
e.g.: For LEY25EA-100C-R1CD17T
Enter
“
LEY25EA-100
”
.
BC-E
Blank controller *
*
Specified software (JXC-BCW) is required.