SMC Networks ITV2000 series Скачать руководство пользователя страница 3

Microprocessor-Controlled Electro-Pneumatic Regulator 

ITV2000

E A S Y   P R O G R A M M I N G   G U I D E

Page 3

last updated 11/03/03 10:05 AM

I

NPUT 

S

IGNAL

 

C

URRENT 

S

IGNAL 

T

YPES 

(ITV20

-0 , ITV20

-1 )

Supply Voltage VS

Input Signal A

24VDC (ITV20 0)

12VDC (ITV20 1)

4~20mA (ITV20

-0

)

0~20mA (ITV20

-1 )

 

V

OLTAGE 

S

IGNAL 

T

YPES 

(ITV20

-2 , ITV20

-3 )

Supply Voltage VS

Input Signal V

IN

24VDC (ITV20 0)

12VDC (ITV20 1)

0~5VDC (ITV20

-2 )

0~10VDC (ITV20

-3 )

K

EYLOCK 

F

EATURE

locked

unlocked

The ITV has a key lock feature, allowing the user to disable the setting keys. This

is helpful in preventing unauthorized setting changes. By default, the keys are locked
when power is turned on. The keys must be unlocked to modify the setting information.
The display will show 

L

OC

  if a key is pressed while the keys are locked.

T

U

NLOCK

:

¬ 

Press and hold the down key for 2 seconds or longer. The display will blink 

L

OC

.

­

 Press the set key to unlock the keys, or

®

 Press the up key to cancel.

T

L

OCK

:

¬ 

Press and hold the up key for 2 seconds or longer. The display will blink 

U

NL

.

­

 Press the set key to lock the keys, or

®

 Press the down key to cancel. 

Содержание ITV2000 series

Страница 1: ...UIDE Page 1 last updated 11 03 03 10 05 AM MICROPROCESSOR CONTROLLED E P REGULATOR ITV2000 CONTENTS 1 LAYOUT IDENTIFICATION 2 WIRING 3 INPUT SIGNAL 4 KEY LOCK FUNCTION 5 SET POINT PROGRAMMING 6 ADJUST...

Страница 2: ...E Page 2 last updated 11 03 03 10 05 AM LAYOUT IDENTIFICATION WIRING Please be careful when connecting the four cable wires Improper wiring will damage the internal circuitry PIN WIRE COLOR DESCRIPTIO...

Страница 3: ...e ITV has a key lock feature allowing the user to disable the setting keys This is helpful in preventing unauthorized setting changes By default the keys are locked when power is turned on The keys mu...

Страница 4: ...THE MINIMUM PRESSURE F_1 Press the UP and DOWN keys until the display shows the desired minimum pressure Press and release the SET key to continue to the next step 3 SET THE MAXIMUM PRESSURE F_2 Press...

Страница 5: ...minimum pressure zero adjust maximum pressure span adjust MONITOR OUTPUT The ITV is available with one of three different monitor output signals ANALOG ITV20 1 Linear analog pressure monitor signal 1...

Страница 6: ...e UP and DOWN keys for 3 seconds or longer to reset SPECIFICATIONS Supply Pressure set pressure 14 5psi to 145psi 1 Output Pressure 0 725 14 5psi ITV201 0 725 72 5psi ITV203 0 725 130 5psi ITV205 Maxi...

Страница 7: ...62 FAX 80a 222 5221 SMC PneumaticsInc Rochester 245 SummitPointDrive Henrietta NY 14467 Tel 716 321 1300 FAX 716 321 1865 SMC Pneumaticslnc S F 85 NicholsonLane SanJose CA 95134 Tel 408 943 9600 FAX 4...

Отзывы: