16 / 17
FGX-OM-F001-A
[4] Microswitch for Differential Pressure Indication Switch
(1) Contact specifications
(4) Electric circuit
(2) Rating
(5) Terminal type
(3) Other performance
[5] Maintenance space
Item
Specifications
Inrush
current
Normally closed
Max. 15A
Normally open
-
Minimum applicable load
DC5V 160mA
Table 6-8
Contact specifications
Rated voltage
Resistance load
250 VAC
5A
Table 6-9
Rating
Item
Specifications
Insulation resistance
100 M
Ω
or more
(Measured by 500 VDC, insulation resistance
tester. )
Contact resistance
30m
Ω
or less
Withstand
voltage
Between terminals with
the same pole
AC1000V 50/60Hz 1min
Between charged metal
part and ground
AC1500V 50/60Hz 1min
Between each terminal
and non-charged metal
part
AC1500V 50/60Hz 1min
Table 6-10
Other specifications
Soldering terminal
(N. C. and N. O. common)
NC
NO
COM
Table 6-11
Maintenance space
Port size
Dimension to draw the element
Drain flushing dimension
06,08
290mm from the lower end of the bowl
100mm from the lower end
of the bowl
10,12
380mm from the lower end of the bowl
16
430mm from the lower end of the bowl
20,24
540mm from the lower end of the bowl
Precautions
1. Connect desired wiring to the micro switch
indication symbols 1 (COM. ) , 2 (N. C. ) ,and 3 (N.
O. ) . 2. When a protection mechanism is required,
take appropriate considerations on the electric circuit
since the micro switch is a type of non-reset.