-8-
No.EX
※※
-OMH0025-C
Model Indication and How to Order
•Output block
EX9-OE
Output type
1
Source / PNP (negative common)
2
Sink / NPN (positive common)
Power supply type
T
Internal power supply from SI unit (for low wattage load)
P
External power supply type (for high wattage load)
: A Power block is required.
•Power block
EX9-PE1
Product Outline
The EX9 series is connected between an applicable SI unit and the valve manifold to operate equipment such
as a solenoid valve or relay. An Output block and Power block are available.
•Output block
Type
Part No.
Description
Remarks
For low
wattage
load
EX9-OET1
EX9-OET2
Current Output to connected load
(output equipment) or manifold valves
using the power supply from the SI unit.
Usable load wattage is limited to 1.5 W
because
power is supplied by the SI unit.
When the load is up to 12 W, use both the Power
block and a high wattage load Output block.
For high
wattage
load
EX9-OEP1
EX9-OEP2
Current Output to connected load
(output equipment) using an external
power supply.
For use with the Power block (EX9-PE1) which
uses an external power supply.
: Limited to 1.0 W when the EX500-Q
02 SI unit (page
54
) is connected.
•Power block
Type
Part No.
Description
Remarks
-
EX9-PE1
Provides an external power supply to
the Output block for high wattage load.
For use with the Output block for high wattage
load.