U side
D side
1 2 3 4 5
Valve stations
1
3
0
2
3
5
7
1
0
2
4
8
A
B
B
12
A
14
A
B
B
12
A
14
A
B
B
12
A
14
A
B
B
12
A
14
A
B
B
12
A
14
Wireless unit
(Base module)
EX600-WEN1
Digital output unit
EX600-DYPB
Digital input unit
EX600-DXPD
End plate (D side)
EX600-ED4
2-position single
SY3100-5U1 (3 sets)
2-position double
SY3200-5U1 (2 sets)
D side
U side
Wireless unit (Base module)
EX600-WEN1
End plate (D side)
EX600-ED4
End plate (U side)
EX600-EU1
1
3
0
2
3
5
7
1
0
2
4
8
D side
U side
Wireless unit
(Remote module)
EX600-WSV1
End plate (D side)
EX600-ED4
End plate (U side)
EX600-EU1
Digital output unit
EX600-DYPB
Digital input unit
EX600-DXPD
U side
D side
1 2 3 4 5
Valve stations
1
3
0
2
3
5
7
1
0
2
4
8
A
B
B
12
A
14
A
B
B
12
A
14
A
B
B
12
A
14
A
B
B
12
A
14
A
B
B
12
A
14
2-position single
SY3100-5U1 (3 sets)
2-position double
SY3200-5U1 (2 sets)
Wireless unit
(Remote module)
EX600-WSV1
Digital output unit
EX600-DYPB
Digital input unit
EX600-DXPD
End plate (D side)
EX600-ED4
Wireless System
Modular Type
EX600-W
Series
Ordering Example of the Base Module
Ordering Example of the Remote Module
Base module: Without valve manifold and input/output unit
Remote module: Without valve manifold and with input/output unit
Manifold with base module: With input/output unit
Manifold with remote module: With input/output unit
SS5Y3-10S6WE72-05B-C6
(Type 10 5-station manifold base, Base EtherNet/IP™ compatible)
Negative common, M12 connector IN/OUT pin arrangement 1, I/O unit: 2 stations
*
SY3100-5U1
·················
3 sets (2-position single part no.)
*
SY3200-5U1
·················
2 sets (2-position double part no.)
*
EX600-DXPD
················
1 set I/O unit part no. (Stations 1)
*
EX600-DYPB
·················
1 set I/O unit part no. (Stations 2)
EX600-ED4
·······························
1 set
EX600-WEN1
·····························
1 set
EX600-EU1
·······························
1 set
EX600-ED4
·······························
1 set
EX600-DXPD
·····························
1 set
EX600-DYPB
·····························
1 set
EX600-WSV1
·····························
1 set
EX600-EU1
·······························
1 set
SS5Y3-10S6WS72-05B-C6
(Type 10 5-station manifold base, remote)
Negative common, M12 connector IN/OUT pin arrangement 1, I/O unit: 2 stations
*
SY3100-5U1
·················
3 sets (2-position single part no.)
*
SY3200-5U1
·················
2 sets (2-position double part no.)
*
EX600-DXPD
················
1 set I/O unit part no. (Stations 1)
*
EX600-DYPB
·················
1 set I/O unit part no. (Stations 2)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
· For details, refer to the catalog of each valve series.
· The manifold part number cannot be selected when ordering from Malaysia according
to Malaysian laws. The wireless unit (base module) needs to be ordered separately.
· Products should be ordered separately and
assembled by the customer.
· Products should be ordered separately and
assembled by the customer.
· For details, refer to the catalog of each valve series.
· The manifold part number cannot be selected when ordering from Malaysia according
to Malaysian laws. The wireless unit (remote module) needs to be ordered separately.
26
EXW1
Series
Accessories
Made to Or
der
EX600-W
Series
Accessories
Tec
hnical Data
Sp
eci
fic
P
ro
duc
t
P
re
cau
tio