Страница 1: ...Reduced wiring system EX500 GMJ1 Instruction Manual CC Link Compatible GW Unit URL http www smcworld com EX OMI0026...
Страница 2: ...pecification 24 Display 25 Input Unit Manifold Part Names 26 Dimensions 27 Installation 28 Specification 29 Wiring 30 Display 31 EX9 Series General Purpose Output Block Part Names 32 Dimensions 33 Mou...
Страница 3: ...system by adding different type of protection such as mechanical protection Check that the interlock circuit is working normally Otherwise accident caused by malfunction can result Before performing...
Страница 4: ...ace near power cable Do not operate the product in a place where there is a source of surge Use a surge absorbing element built in type to directly drive the load that generates surge voltage such as...
Страница 5: ...d valve for input devices such as sensor and for controlling GW SI by using power supply connector cable Note1 Display the power supply status and communication status with PLC Note2 Station number sw...
Страница 6: ...branch total extended length 10m or less Number of stations occupied Station type 3 stations Remote device station Transmission speed 156kbps 625kbps 2 5Mbps 5Mbps 10Mbps Cable length between stations...
Страница 7: ...this EX500 is the terminal of CC Link connection connect the terminal resistor Refer to Connection of terminal resistor page 12 in this manual Avoid the mixing of CC Link dedicated high performance c...
Страница 8: ...Gray Wiring continued Power supply wiring Connect the power supply connector cable to the power supply connector of GW unit There are two types of cables different in connector shape straight type and...
Страница 9: ...nnector Power supply connector 1 3 4 5 2 1 3 4 5 2 A Two power supply system B Single power supply system Branch wiring wiring to communication ports For wiring with solenoid valves or input devices c...
Страница 10: ...unit for SV VQC series Connector C1 0 Branch cable with M12 connector Connector C2 1 Input unit manifold Manifold valve with SI unit for SV VQC series Terminal plug NOTE When no Input unit is connecte...
Страница 11: ...has no received data Lights on COM D is receiving data Lights off COM D has no received data Display Description NOTE When connecting manifold valve only without connecting Input unit manifold LEDs o...
Страница 12: ...ate solenoid valves relays etc in combination with EX9 series general purpose output block For how to use it refer to section EX9 Series General Purpose Output Block page 32 in this manual SI unit for...
Страница 13: ...dually Note 1 For mounting installation methods of solenoid valve manifold etc refer to the catalogs instruction manuals technical data etc of each valve series When connecting general purpose output...
Страница 14: ...alve series Cassette Tie rod 40 50 63 80 100 125 Series Manifold Inner diameter of applicable cylinder tube mm Max 8 stations Single solenoid valve General purpose output block EX500 Q 02 only Max 16...
Страница 15: ...ector 5 Connects with sensor Note1 Indicator LED 6 Indicates sensor signal status Note2 Marker 7 To be used for writing input No etc End block 8 Completes the end of Input unit manifold DIN rail 9 To...
Страница 16: ...2 3 4 5 6 7 8 Specification Specifications for Input unit Connected block Current source type input block PNP input block or Current sink type input block NPN input block Connected block stations Max...
Страница 17: ...onnecting sensors confirm the specification of output signal carefully Otherwise malfunction can result The key position for mounting sensor connector is as shown to the right Consider this key positi...
Страница 18: ...eries SI unit for VQC series EX500 Q 02 Output connector 1 Connects with output device Note1 Indicator LED 2 Indicates the output status Note2 Part name No Application Note1 For wiring method refer to...
Страница 19: ...f output block stations 1 2 3 4 5 6 7 8 The above dimensions indicate when one unit of power block width 21mm is combined For details refer to the instruction manuals technical data etc of EX9 series...
Страница 20: ...output devices DC24V Power supply for output devices DC24V 2 Power supply for output devices 0V Power supply for output devices 0V 3 4 5 Power supply for sensor DC24V Power supply for sensor 0V Groun...
Страница 21: ...is unused If this terminal plug is not used COM LED of GW unit does not light on EX500 AC000 S How to order 1 7 6 5 4 3 2 8 M12 16 44 7 Plug Connector Pin Layout Waterproof cap Mounted on unused ports...
Страница 22: ...to the branch of unlit COM port and the branch cable with M12 connector is connected to the Input unit When connecting no Input unit connect a terminal plug Item No Solution Corrective action PWR LED...