-20-
No.D-
※
S-OMU0002-A
•Product individual parameters
Index
(decimal
number)
Subindex
Access
1
Parameter name
Format
Length
Initial
value
DS
2
Selection range
Value/Range
0x003C
(60)
1
R/W
BDC1
SetPoint1
bit(16)
16 bit
3
Y
3
2
R/W
SetPoint2
bit(0)
16 bit
3
Y
3
0x003D
(61)
1
R/W
BDC1
Logic
bit(24)
8 bit
0
Y
4
2
R/W
Mode
bit(16)
8 bit
0
Y
5
3
R/W
Hysteresis
bit(0)
16 bit
10
Y
1 to 400
0x003E
(62)
1
R/W
BDC2
SetPoint1
bit(16)
16 bit
3
Y
3
2
R/W
SetPoint2
bit(0)
16 bit
3
Y
3
0x003F
(63)
1
R/W
BDC2
Logic
bit(24)
8 bit
0
Y
4
2
R/W
Mode
bit(16)
8 bit
0
Y
5
3
R/W
Hysteresis
bit(0)
16 bit
10
Y
1 to 400
0x4000
(16384)
1
R/W
BDC3
SetPoint1
bit(16)
16 bit
3
Y
3
2
R/W
SetPoint2
bit(0)
16 bit
3
Y
3
0x4001
(16385)
1
R/W
BDC3
Logic
bit(24)
8 bit
0
Y
4
2
R/W
Mode
bit(16)
8 bit
0
Y
5
3
R/W
Hysteresis
bit(0)
16 bit
10
Y
1 to 400
0x4002
(16386)
1
R/W
BDC4
SetPoint1
bit(16)
16 bit
3
Y
3
2
R/W
SetPoint2
bit(0)
16 bit
3
Y
3
0x4003
(16387)
1
R/W
BDC4
Logic
bit(24)
8 bit
0
Y
4
2
R/W
Mode
bit(16)
8 bit
0
Y
5
3
R/W
Hysteresis
bit(0)
16 bit
10
Y
1 to 400
1:
"R" means Read and "W" means Write.
2:
Y: Included in DS (data storage), N: Not included in DS.
3
: Refer to initial value and selection range. (P.
4
: 0: Normal output, 1: Reversed
5
: 0: Deactivated, 1: Single point mode, 2: Window mode, 3: Two points mode, 128: Auto Switch mode
For all operation modes, it is necessary to satisfy the following conditions.
•(SP1 + hysteresis < measuring range) and (SP2 + hysteresis < measuring range) and
(SP1 - hysteresis ) > 0) and (SP2 - hysteresis) > 0
•At Window mode (hysteresis < [SP1 - SP2])
•(SP1 + 1.5 mm + 1.5 x hysteresis < measuring range) and (SP1 - 1.5 mm - 1.5 mm x hysteresis > 0)