6.How to mount / Mounting bracket
(Sensor)
Each actuator has a specified mounting bracket when
mounted to the auto switch. “How to mount/Mount bracket”
depends on actuator type and tube I.D. Please refer to the
actuator catalogue. When an auto switch is mounted for the
first time, please ensure the actuator is of the magnet built-in
type, then prepare brackets that correspond to the actuator.
The application actuator : CDQ2
-XB14.
7.Basic wiring
5.Names and Functions of Individual Parts
Indicator lamp
Heat resistant cord
Mounting hole
S
M
C
2
2
4
0
1
1
3
.4
3
.4
(64.5)
0.7
3
6
.2
(4)
3000
21.6
8
1
5
4
7
3.8
3000(5000)
Indicator lamp
Heat resistant cord
Slide the auto switch mounting nut inserted into the mounting rail
and set it at the auto switch mounting position.
Fit the convex part of auto switch mounting arm into the concave
part of auto switch mounting rail. Then slide the switch over the nut.
(CDQ2 series:Fit the convex part of auto switch mounting arm
through the auto switch spacer into the concave part of auto switch
mounting rail.)
Push the auto switch mounting screw lightly into the mounting nut
through the hole of auto switch mounting arm.
After reconfirming detection position, tighten the mounting screw to
secure the auto switch. (Tightening torque of M3 screw should be
0.5 to 0.7N
•
m.)
Modification of the detecting position should be made referring to item
.
8.Exterior dimension
9.Check flow
When detection failure occurs(stay ON/OFF), please check based on
the following flow chart.
D-#S-TFI88GB-A
A
B
C
D
B
B
A
C
A
B
C
D
---
---
---
---
(Amplifier)
The Solid state switch amplifier unit should mounted on DIN rail.
How to mount on DIN terminal
As described below, hook the bottom of the body on the DIN rail,
and then push and hold the unit down in direction of arrow.
For removal, release the unit from the DIN rail using a screw driver.
Remove
Mount
Indicator lamp
Mounting hole
Heat resistant cord
Switch mounting screw
Switch spacer
Switch
mounting
nut
Auto switch
Remove
Mount
Switch
main
circuit
DC(+)
Brown
OUT
Black
DC(-)
Blue
Power
supply
Load
HE
AT
PR
OO
F
AU
TO
SW
ITC
H
AM
PL
IFI
RE
MO
DE
PO
SI
TIO
N
Indicator lamp
Heat resistant cord
Problem occurs
Trouble
condition
Indicator
lamp lights
Wiring
(output) check
Stay ON (Sometimes OFF)
Stay OFF(Sometimes ON)
Normal
Normal
Abnormal
Stay OFF
Source voltage
or load voltage
Normal
Abnormal
Stay OFF
Normal
Normal
Abnormal
Replace the Switch
Indicator
lamp lights
Stay ON
Switch output failure (replace)
Check and correct wiring
Switch failure
Replace actuator. Detectable magnet field not adequate (No magnet)
Mark
O
P
Q
R
S
T
U
V
W
X
Y
Z
Month
January
February
March
April
May
June
July
August
September
October
November
December
Mark
J
K
L
M.
..
Year
2005
2006
2007
2008
..
.
Year
Month
Manufacturer’s batch marking
AUSTRIA
(43) 2262 62280
NETHERLANDS
(31) 20 531 8888
BELGIUM
(32) 3 355 1464
NORWAY
(47) 67 12 90 20
CZECH REP.
(420) 541 424 611
POLAND
(48) 22 211 9600
DENMARK
(45) 7025 2900
PORTUGAL
(351) 21 471 1880
FINLAND
(358) 207 513513
SLOVAKIA
(421) 2 444 56725
FRANCE
(33) 1 6476 1000
SLOVENIA
(386) 73 885 412
GERMANY
(49) 6103 4020
SPAIN
(34) 945 184 100
GREECE
(30) 210 271 7265
SWEDEN
(46) 8 603 1200
HUNGARY
(36) 23 511 390
SWITZERLAND
(41) 52 396 3131
IRELAND
(353) 1 403 9000
UNITED KINGDOM
(44) 1908 563888
ITALY
(39) 02 92711
URL http://www.smcworld.com (Global) http://www.smceu.com (Europe)
Specifications are subject to change without prior notice from the manufacturer.
The descriptions of products in this document may be used by other companies.
© SMC Corporation All Rights Reserved.
Contact