6. Operation and Adjustment
6-1. Pressure regulation
Knob
Orange mark
Pilot valve
IN
OUT
Manual override
Exhaust port
(1) Pull the knob in the arrow direction
for unlocking, revealing an orange
mark.
(3) After adjusting pressure, lock the knob
by pushing it in the arrow direction.
* Make sure the handle is fully loosened
before moving on to step (2).
(2)
Turn on the power to the pilot valve and supply
pressure to the IN side of the product.
Then, turning the handle clockwise in the unlocked
state increases the pressure on the outlet side.
Note) Always set the pressure in the upward
direction (arrow direction).
Otherwise, it may cause insufficient
set pressure.
* The state shown in (3), with the pilot valve
turned on, is called "standby mode
”
.
(4
) When the power to the pilot valve is turned off
in the state (3), some air is exhausted from the
exhaust port and the pressure at the outlet side
becomes the same as the supply pressure.
* The state shown in (4) is called "operation mode
”
.
With air consumption downstream of the product,
it is possible to switch to each mode by switching
the pilot valve ON/OFF or by operating the manual
override.
- Operation mode
→
When solenoid valve is OFF or the
manual override is not operated.
- Standby mode
→
When solenoid valve is turned on or the
manual override is operated.
- 13 -