Activated Carbon Filter 

       

  Safety Instructions

 

 

These safety instructions are intended to prevent hazardous situations and/or equipment damage.

 

These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.”

 

They  are  all  important  notes  for  safety  and  must  be  followed  in  addition  to  International  Standards 
(ISO/IEC)

*1)

 , and other safety regulations.

 

*1) ISO 4414: Pneumatic fluid power -- General rules relating to systems.

 

   

ISO 4413: Hydraulic fluid power -- General rules relating to systems.

 

   

IEC 60204-1: Safety of machinery -- Electrical equipment of machines .(Part 1: General requirements)

 

   

ISO 10218: Manipulating industrial robots -Safety.

                                                                                 

 

 

  etc.

 

     

 
 

Caution

 

Caution

 indicates a hazard with a low level of risk which, if not avoided, could result 

in minor or moderate injury.

 

 
 

Warning

 

Warning

 

indicates a hazard with a medium level of risk which, if not avoided, could 

result in death or serious injury.

 

 
 

Danger

 

Danger

 

indicates a hazard with a high level of risk which, if not avoided, will result 

in death or serious injury.

 

 

Warning

 

1. The compatibility of the product is the responsibility of the person who designs the equipment or 

decides its specifications.

 

Since  the  product  specified  here  is  used  under  various  operating  conditions,  its  compatibility  with  specific 
equipment must be decided by the person who designs the equipment or decides its specifications based on 
necessary analysis and test results.   
The expected performance and safety assurance of the equipment will be the responsibility of the person who 
has determined its compatibility with the product.   
This  person  should  also  continuously  review  all  specifications  of  the  product  referring  to  its  latest  catalog 
information, with a view to giving due consideration to any possibility of equipment failure when configuring the 
equipment.

 

2. Only personnel with appropriate training should operate machinery and equipment.

 

The product specified here may become unsafe if handled incorrectly.

 

The  assembly,  operation  and  maintenance  of  machines  or  equipment  including  our  products  must  be 
performed by an operator who is appropriately trained and experienced.

 

3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.

 

1.The inspection and maintenance of machinery/equipment should only be performed after measures to   

prevent falling or runaway of the driven objects have been confirmed.

 

2.When the product is to be removed, confirm that the safety measures as mentioned above are implemented 
    and the power from any appropriate source is cut, and read and understand the specific product precautions 
    of all relevant products carefully.

 

3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.

 

4. Contact SMC beforehand and take special consideration of safety measures if the product is to 

be used in any of the following conditions.

 

1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to 
    direct sunlight.

 

2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, 

  vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and 
  beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or 
  other applications unsuitable for the standard specifications described in the product catalog.

 

3. An application which could have negative effects on people, property, or animals requiring special safety   

analysis.

 

4.Use  in  an  interlock  circuit,  which  requires  the  provision  of  double  interlock  for  possible  failure  by  using  a 

mechanical protective function, and periodical checks to confirm proper operation. 

 

 

-2- 

Содержание AMK50 Series

Страница 1: ...Doc No AMX OMZ0095 PRODUCT NAME Activated Carbon Filter MODEL Series Product Number AMK50 F N 06 F N 10 B R Z D AMK60 F N 10 B R Z D...

Страница 2: ...tions Replacement parts 9 6 Bowl assembly specifications 10 6 1 Bowl assembly for AMK50 10 6 2 Bowl assembly for AMK60 10 7 Assembly of Optional parts 11 8 Troubleshooting 12 9 How to Replace the Comp...

Страница 3: ...f equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly...

Страница 4: ...e failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are exclud...

Страница 5: ...irborne particles from the operating environment entering into the compressed air stream or foreign matter may adhere to the workpiece during the air blow 5 If the air equipment is mounted on the outl...

Страница 6: ...s and fittings etc be certain that chips from the pipe threads and sealant do not get inside the pipe When a sealant tape is used leave 1 5 to 2 thread ridges exposed at the end of the threads 3 Conne...

Страница 7: ...the operation manual Incorrect handling of the product may cause breakage or operation failure of the equipment or device 3 Do not touch the product when operating at high temperature 40 to 60oC The o...

Страница 8: ...and 65 of relative humidity The compressed air quality class on the inlet side is 1 4 2 Note 3 Based on ISO8573 1 2010 Compressed air Part1 Contaminants and purity classes 7 AMK50 AMK60 3 4 1 1 2200L...

Страница 9: ...Nil Without mounting option B With bracket Nil Flow direction Left to right R Flow direction Right to left Nil Pressure unit MPa Temp unit o C Z Pressure unit psi Temp unit o F Note2 Note2 Thread typ...

Страница 10: ...tions AMK50 AMK60 Bracket assemblyNote2 Note1 Note2 Assembly of the mounting bracket 2 types and set screw 2 pcs Refer to the 7 Assembly of Optional parts P12 for mounting the bracket assembly The num...

Страница 11: ...tandard symbol 10 Note1 Part No includes Bowl seal Refer to 10 Disassembly Drawing P15 Appearance and Part No Note1 Part No includes Bowl seal Refer to 10 Disassembly Drawing P15 Appearance and Part N...

Страница 12: ...the tightening torque Insert bracket A from the front side of the product so that the finger of the bracket A engages with the groove and the bottom of the body Mounting of bracket A see drawing on th...

Страница 13: ...drain accumulated in the container and wipe off the oil content in the pipes Then replace the element of the activated carbon filter P13 to 14 1 From the filter installed on the inlet side particles...

Страница 14: ...h fingers two locations of the bowl with the body 6 Install the flange to the body temporarily tighten four mounting screws and then tighten them diagonally and evenly to secure the flange AMK50 AMK60...

Страница 15: ...bowl assembly by referring to the section 9 1 Bowl assembly Replacement P13 Assembly 2 Install the replacing element and bowl seal in the bowl assembly Mount the bowl assembly by referring to the sect...

Страница 16: ...10 Disassembly Drawing 15 Body I N OUT AMK50 AMK60 Bowl seal Element Bowl assembly Mounting screws 4 pieces...

Страница 17: ...J M N Q R S T U V AMK50 3 4 1 90 222 32 45 30 45 70 66 40 5 11 13 113 3 2 52 5 AMK60 1 90 299 1 32 45 30 45 70 66 40 5 11 13 113 3 2 52 5 Model No Option specifications Bracket mount Standard specifi...

Страница 18: ...u Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacture...