Caution
1. About the mounting orientation of the products
Make sure to install this product on horizontal piping. If it is in-
stalled diagonally, laterally, or upside down, the drain separa-
ted by the element will splash to the outlet side.
Mounting
Selection
Caution
1. About the system composition of purifying com-
pressed air
Compressed air generally contains particulate contaminants
as listed below, though there are some variations due to the
compressor type and specifications. Determine the system
configuration according to the desired cleanliness of com-
pressed air and application, while referring to the “Air Prepara-
tion Equipment Selection Guide” (pages 2 and 3).
[Particulate contaminants in compressed air]
• Water (drainage)
• Dust sucked from ambient air
• Degenerated oil from compressor
• Solid foreign matter such as rust inside piping and oil
2. Select according to the maximum flow consump-
tion.
When compressed air is used for air blow, etc., find the maxi-
mum air consumption before selecting the size of the AM
series. (If compressed air exceeding the maximum flow rate is
supplied, it can result in decline of the cleanliness of com-
pressed air or element damage.)
Caution
Piping
1. Connect it with IN and OUT ports in proper location.
It does not work with the connection reversed.
In the case of the AFF2C to 22C, 37B, 75B, AM
150C to
550C, 650, 850
Verify the direction of the flow of the compressed air and the
“ ” or “ ” mark that indicates the inlet of the product before
connecting. It cannot be used if connected in the opposite di-
rection.
IN
OUT
Symbol which indicates the flow of
compressed air
or
In the case of the AFF75A to 220A, AMD801, 901, 800, 900,
1000
INLET and OUTLET of compressed air is labeled on the side
of flange. Be sure to connect correctly.
2. Use an air blower to flush the piping before con-
necting the piping.
Use an air blower to thoroughly flush the piping, or wash the
piping to remove any cutting chips, cutting oil, or debris from
inside the piping before connecting them.
3. Wrapping of sealant tape
When screwing in the pipes or fittings, make sure to prevent
cutting chips or the sealant material on the threaded portion of
the pipe from entering the piping. If sealant tape is to be used,
leave about 1.5 to 2 ridges of threads uncovered.
4. Modular connection
Mount the attached bracket on one side when connecting 2
sets. Mount the attached brackets on both sides when con-
necting 3 sets or more. As a guideline for the number of
brackets, one bracket should be mounted for every 2 prod-
ucts.
Series
AM
/AFF
Specific Product Precautions 2
Be sure to read before handling.
Refer to front matters 42 and 43 for Safety Instructions and pages 6 to 8 for Air
Preparation Equipment Precautions.
217
AT
IDFA
IDFB
ID
IDG
AMG
AFF
AM
AMD
AMH
AME
AMF
SF
SFD
LLB
AD
GD
HAA
HAW
IDF
IDU
P0141-P0220-E.qxd 08.11.6 1:52 PM Page 217
Содержание AFF Series
Страница 38: ...178 P0141 P0220 E qxd 08 11 6 1 51 PM Page 178...
Страница 91: ...305 AC AF AR AL AW A G AV AF800 AF900 P0295 P0364 E qxd 08 11 6 2 05 PM Page 305...
Страница 95: ...309 AC AF AR AL AW A G AV AF800 AF900 P0295 P0364 E qxd 08 11 6 2 05 PM Page 309...
Страница 99: ...313 AC AF AR AL AW A G AV AF800 AF900 P0295 P0364 E qxd 08 11 6 2 05 PM Page 313...
Страница 103: ...317 AC AF AR AL AW A G AV AF800 AF900 P0295 P0364 E qxd 08 11 6 2 05 PM Page 317...
Страница 123: ...337 AC AF AR AL AW A G AV AF800 AF900 P0295 P0364 E qxd 08 11 6 2 06 PM Page 337...
Страница 142: ...356 P0295 P0364 E qxd 08 11 6 2 06 PM Page 356...
Страница 150: ...364 P0295 P0364 E qxd 08 11 6 2 06 PM Page 364...
Страница 171: ...385 AC AF AR AL AW A G AV AF800 AF900 P0365 P0446 E qxd 08 11 6 2 09 PM Page 385...