T
ROUBLESHOOTING
A-2
Diagnosing Power Problems with the LEDs
The Power and RPS LEDs work in combination to indicate power status
as follows.
Stack Link LED is
Flashing Green/Amber
•
The uplink/downlink has failed.
•
For the indicated stack link, check that the stacking
cables are properly connected. Replace the stacking
cable if necessary.
•
Power cycle the switch to try and clear the condition.
Link LED is Off
•
Verify that the switch and attached device are powered
on.
•
Be sure the cable is plugged into both the switch and
corresponding device.
•
Verify that the proper cable type is used and its length
does not exceed specified limits.
•
Check the adapter on the attached device and cable
connections for possible defects. Replace the defective
adapter or cable if necessary.
Table A-2 Power/RPS LEDs
Power LED RPS LED
Status
Green
Green
Internal power functioning normally; RPS is present.
Green
Amber
Internal power functioning normally; RPS plugged in but
faulty.
Green
Off
Internal power functioning normally; RPS not plugged in.
Amber
Green
Internal power faulty; RPS delivering power.
Off
Off
Both internal power and RPS unplugged or not functioning.
Table A-1 Troubleshooting Chart
(Continued)
Symptom
Action
Содержание 8824M
Страница 2: ......
Страница 18: ...TABLE OF CONTENTS xiv Glossary Index ...
Страница 50: ...INSTALLING THE SWITCH 3 14 ...
Страница 62: ...MAKING NETWORK CONNECTIONS 4 12 ...
Страница 78: ...SPECIFICATIONS C 6 ...
Страница 82: ...MONTAGE RACK MOUNTING INSTRUCTIONS GERMAN D 4 ...
Страница 84: ...ORDERING INFORMATION E 2 ...
Страница 94: ...INDEX Index 4 ...
Страница 95: ......