B
ASIC
C
ONFIGURATION
3-39
Command Attributes
•
System Log Status
– Enables/disables the logging of debug or error
messages to the logging process. (Default: Enabled)
•
Flash Level
– Limits log messages saved to the switch’s permanent flash
memory for all levels up to the specified level. For example, if level 3 is
specified, all messages from level 0 to level 3 will be logged to flash.
(Range: 0-7, Default: 3)
•
RAM Level
– Limits log messages saved to the switch’s temporary RAM
memory for all levels up to the specified level. For example, if level 7 is
specified, all messages from level 0 to level 7 will be logged to RAM.
(Range: 0-7, Default: 7)
Note:
The Flash Level must be equal to or less than the RAM Level.
Table 3-3 Logging Levels
Level
Severity Name
Description
7
Debug
Debugging messages
6
Informational
Informational messages only
5
Notice
Normal but significant condition, such as cold start
4
Warning
Warning conditions (e.g., return false, unexpected
return)
3
Error
Error conditions (e.g., invalid input, default used)
2
Critical
Critical conditions (e.g., memory allocation, or free
memory error - resource exhausted)
1
Alert
Immediate action needed
0
Emergency
System unusable
* There are only Level 2, 5 and 6 error messages for the current firmware release.
Содержание 8724ML3 - annexe 1
Страница 2: ......
Страница 26: ...TABLE OF CONTENTS xxvi ...
Страница 64: ...MANAGING SYSTEM FILES 2 18 ...
Страница 366: ...CONFIGURING THE SWITCH 3 302 Web Click Routing Protocol RIP Statistics Figure 3 132 RIP Statistics ...
Страница 400: ...CONFIGURING THE SWITCH 3 336 ...
Страница 798: ...SOFTWARE SPECIFICATIONS A 6 ...
Страница 802: ...TROUBLESHOOTING B 4 ...
Страница 812: ...GLOSSARY Glossary 10 ...
Страница 818: ...INDEX Index 6 ...
Страница 819: ......