Maximum Current
0.2A
﹫
110 VAC
0.1A
﹫
240 VAC
Standards
ANSI/ IEEE 802.3
ANSI/ IEEE 802.3u
ANSI/ IEEE 802.3ab
ANSI/ IEEE 802.3z
EMC/ Safety Compliances
CE Mark
Emissions
FCC Class A
Safety
CSA/UL (C22.2.950, UL 1950)
Limited Warranty
Lifetime
C
ABLE
S
PECIFICATIONS
Cable Type and Connector
10Base-T Cable
Type
Length
Connector
Category 3, 5 UTP/ STP
100m (328 ft)
RJ-45
100Base-TX Cable
Type
Length
Connector
Category 5 UTP/ STP
100m (328 ft)
RJ-45
1000Base-TX Cable
Type
Length
Connector
Category 5 UTP/ STP
100m (328 ft)
RJ-45
RJ-45 Connector Pin Assignmen
t
Caution: DO-NOT
plug a phone jack connector into any RJ-45 port. Use only twisted-pair
cables with RJ-45 connectors that confirm with FCC standards.
An Ethernet or Fast Ethernet twisted-pair link segment requires two pairs (or 4 pairs for
1000Mbps) of wires. Each wire pair is identified by two (or four) different colors. For example,
one wire might be green and other, green with a white stripe.
Each wire pair must be attached to the RJ-45 connector in a specific orientation. Note how the
pins are numbered in the illustration below. Be sure to hold the connectors in the same orientation