C
ABLES
B-6
ANSI/TIA/EIA-TSB-95 Bulletin, “The Additional Transmission
Performance Guidelines for 100 Ohm 4-Pair Category 5 Cabling.”
Note that when testing your cable installation, be sure to include all patch
cables between switches and end devices.
Adjusting Existing Category 5 Cabling to Run 1000BASE-T
If your existing Category 5 installation does not meet one of the test
parameters for 1000BASE-T, there are basically three measures that can be
applied to try and correct the problem:
1. Replace any Category 5 patch cables with high-performance Category
5e or Category 6 cables.
2. Reduce the number of connectors used in the link.
3. Reconnect some of the connectors in the link.
Содержание 6128PL2
Страница 2: ......
Страница 14: ...COMPLIANCESS xiv ...
Страница 20: ...xx ...
Страница 28: ...ABOUT THE TIGERSWITCH 1 8 ...
Страница 36: ...NETWORK PLANNING 2 8 ...
Страница 46: ...INSTALLING THE SWITCH 3 10 ...
Страница 58: ...MAKING NETWORK CONNECTIONS 4 12 ...
Страница 70: ...SPECIFICATIONS C 4 Safety UL CUL UL 60950 1 CSA 22 2 NO60950 1 TUV GS EN60950 1 CB IEC60950 1 ...
Страница 72: ...ORDERING INFORMATION D 2 ...
Страница 82: ...Glossary 6 ...
Страница 85: ...INDEX Index 3 W Web based management 1 3 ...
Страница 86: ...INDEX Index 4 ...
Страница 87: ......