manualshive.com logo in svg
background image

50-VFE-SMY62EN

 

 

Page 1 of 4 

 

 

Instruction Manual   

 

Solenoid operated 3 and 5 port valves 

50-VFE/VPE-X60, 50-VFE3#90-X60 NAMUR 

 

 

 
For ISO symbols see section 3.4. 
 
The  intended  use  of  this  product  is  to  provide  directional  control  to 
pneumatic actuators (or similar industrial pneumatic equipment).

 

1 Safety Instructions 

1.1  General safety instructions 

These  safety  instructions  are  intended  to  prevent  hazardous  situations 
and/or  equipment  damage.  These  instructions  indicate  the  level  of 
potential hazard with the labels of “Caution,” “Warning” or “Danger.” 
They are all important notes for safety and must be followed in addition 
to International  Standards (ISO/IEC)

 *1)

, and other safety regulations. 

*1)

 ISO 4414: Pneumatic fluid power - General rules relating to systems.  

ISO 4413: Hydraulic fluid power - General rules relating to systems. 
IEC 60204-1: Safety of machinery - Electrical equipment of machines.        
(Part 1: General requirements) 
ISO 10218-1: Manipulating industrial robots -Safety. etc. 

  Refer  to  product  catalogue,  Operation  Manual  and  Handling 

Precautions for SMC Products for additional information. 

  Keep this manual in a safe place for future reference. 

 

Caution 

Caution indicates a hazard with a low level of risk which, if 
not avoided, could result in minor or moderate injury. 

 

Warning 

Warning indicates a hazard with a medium level of risk 
which, if not avoided, could result in death or serious injury. 

 

Danger 

Danger indicates a hazard with a high level of risk which, if 
not avoided, will result in death or serious injury. 

  Warning 

 

Always  ensure  compliance  with  relevant  safety  laws  and 
standards. 

  All work must be carried out in a safe manner by a qualified person in 

compliance with applicable national regulations. 

  The product is only suitable for use in Zones 1 and 2. 

  Do not open when energised. 

  Do  not  energise  both solenoids  at  the  same  time,  as  this  can cause 

higher surface temperatures than under normal operating conditions. 

  Do not refurbish the flameproof joints. 

 

 

1 Safety Instructions - continued 

  Electrostatic charge may cause an explosion hazard. 

Avoid  any  actions  that  cause  the  generation  of  electrostatic  charge, 
such as rubbing with a dry cloth on coating face of product. 
Electrostatic charges on the non-metallic parts of the equipment shall 
be avoided. 

  This  product  has  components  made  of  aluminium  alloy.  When 

mounting this product, it must be installed such that, even in the event 
of rare incidents, ignition sources due to impact and friction sparks are 
excluded. 

 

Use of 50-VFE3000/5000-X60 5-port valve as a 3-port valve 

Series 50-VFE3000/5000-X60 valves can be used as normally closed 
(N.C.)  or  normally  open  (N.O.)  3  port  valves  by  closing  one  of  the 
cylinder ports (A or B) with a plug (see Table 1). 
Note: Do not exceed the maximum specified operating frequency. 

 

Plug position 

2(B) port (CYL.1 port) 

4(A) port (CYL.2 port) 

Switching type 

N.C. 

N.O. 

S

o

len

o

id

 

Single 

 

 

 

 

Double 

 

 

Table 1 

 

1.2  Special conditions for safe use 

 Warning 

 The  solenoid  valves  are  provided  with  special  fasteners  of  property 

class A2-50. 

 The  manufacturer  shall  be  contacted  for  information  regarding  the 

flameproof joints. 

 
 

2 Specifications 

2.1  General specifications 

 

SERIES 50-VFE3000/5000-X60 SOLENOID VALVE 

Series 

50-VFE3000 

50-VFE5000 

Fluid 

Air and inert gas 

Operating 
pressure 
range 

2 position single 

0.15 to 0.9 MPa 

3 position 
2 position double 

0.1 to 0.9 MPa 

Ambient and fluid temperature 
(No freezing) 

-10 to 50°C (T5) 
-10 to 40°C (T6) 

Max. operating 
frequency

(1)

 

2 position single 

1 Hz 

2 position double 
3 position 

Lubrication 

Not required 

Mounting position 

Unrestricted 

Impact/Vibration resistance 

(2)

 

150/30 m/s

2

 

 

SERIES 50-VPE500/700-X60 SOLENOID VALVE 

Fluid 

Air and inert gas 

Type of actuation 

N.C or N.O. (convertible) 

Pilot style 

Internal pilot 

External pilot 

Operating pressure range 

0.2 to 0.8 MPa 

Supply 

pressure 

-101.2 kPa to  

0.8 MPa 

External pilot 

pressure 

0.2 to 0.8 MPa 

Ambient and fluid temperature 

(No freezing) 

-10 to 50°C (T5) 

-10 to 40°C (T6) 

Max. operating frequency

(1)

 

1Hz 

Lubrication  

Not required 

Mounting position 

Unrestricted 

Impact/Vibration resistance 

(2)

 

150/30 m/s

2

 

 
 

2 Specifications - continued 

SERIES 50-VFE3#90-X60 NAMUR SOLENOID VALVE 

Fluid 

Air and inert gas 

Type of actuation 

N.C or N.O. (convertible) 

Operating pressure range 

0.15 to 0.9 MPa 

Ambient and fluid temperature 

(No freezing) 

-10 to 50°C (T5) 

-10 to 40°C (T6) 

Max. operating frequency

(1)

 

1Hz 

Lubrication  

Not required 

Mounting position 

NAMUR Interface 

Impact/Vibration resistance 

(2)

 

150/30 m/s

2

 

Note 1) Do not exceed the maximum specified operating frequency. 
 
Note 2) Impact resistance: There should be no malfunction of the valve after testing 
along the valve axis and at right angles to the valve and armature. Carry out each 
test with the valve energised and de-energised (value at initial stage). 
 
Vibration resistance: There should be no malfunction of the valve after testing using 
a 8.3 to  2000Hz sweep along the valve axis  and at  right angles to the  valve  and 
armature. Carry out each test with the valve energised and de-energised (value at 
initial stage). 

 

SERIES 50-VF3-#-X60 PILOT VALVE 

External connection method 

Metal conduit type/ (Cable gland type) 

Coil rated voltage 

AC (50/60 Hz) 

100, 200, 12, 24,   

48, 110, 220, 240V 

DC 

24, 12, 6, 48, 110V 

Allowable voltage fluctuation 

-15% to +10% of rated voltage 

Coil insulation type 

Type B 

Apparent power  AC 

Inrush 

9.1VA (50Hz) 7.8VA (60Hz) 

Holding 

6.2VA (50Hz) 4.6VA (60Hz) 

Power 

consumption 

DC 

3.5W 

3.9W (48, 110V) 

Electric circuit 

Non-polar type 

 
 
 

Batch codes and Construction month: 

The product control number is shown by two characters and two figures. 
The character shows Year and Month of manufacturing. 

 

The figures show a serial number stamp.  
This stamp indicates the year and month of production, the month of the  
production  request  and  the  order  in  which  work  order  has  been 
processed. 
 

3 Installation 

3.1 Installation 

 Warning 

  Do not install the product unless the safety instructions have been read 

and understood. 

 

3.2 Environment 

 Warning 

  The product is only suitable for use in Zones 1 and 2. 

  Do not use in an environment where corrosive gases, chemicals, salt 

water or steam are present. 

  Do not expose to direct sunlight. Use a suitable protective cover. 

  Do not install in a location subject to vibration or impact in excess of 

the product’s specifications. 

  Do not mount in a location exposed to radiant heat that would result in 

temperatures in excess of the product’s specifications. 

  When the solenoid valve is mounted in a control panel or is energised 

for a long time, make sure the ambient temperature is within the valve 
specification range. 

3 Installation - continued 

3.3 Piping 

 Caution 

  Before connecting piping make sure to clean up chips, cutting oil, dust 

etc. 

  When  installing  piping  or  fittings,  ensure  sealant  material  does  not 

enter inside the port. When using seal tape, leave 1 thread

 

exposed 

on the end of the pipe/fitting.  

  Tighten fittings to the specified tightening torque, see Table 2. 

 

Thread 

Tightening Torque (

N•m) 

M5 

1 to 1.5 

1/8 

3 to 5 

1/4 

8 to 12 

3/8 

15 to 20 

1/2 

20 to 25 

Table 2 

 
 

3.4 ISO symbols 

 

50-VPE5(7)42(R) 

 

N.C. 

 

 

N.O. 

 
 

C.O. 

 
 
 
 
 
 
 

 

50-VFE3/5000

 

 
 

5/2 Single 

 
 
 

5/2 Double 

 
 
 

5/3 Closed 

 

centre 

 
 

5/3 Exhaust 

 

centre 

 
 

5/3 Pressure 

 

centre 

 
 
 

3.5 Electrical entry (see Figure 1)

 

The terminal box can be rotated 300° about plane ‘A’. 

 

Loosen screw ‘C’ and rotate the terminal box to the desired position. 

  Re-tighten screw to lock the terminal box in position. 

 
The cover can be rotated 360° about plane ‘B’. 

 

Undo screw ‘D’ and rotate the cover to the desired position – there are 
4 positions 

– in increments of 90°. 

  Re-assemble screw to lock the cover in place. 

 
 
 
 
 
 
 

Co nstructio n

Year / M o nth Jan Feb M ar A pr M ay Jun Jul A ug Sep Oct No v Dec

2019

Xo

XP

XQ

XR

XS

XT

XU

XV

XW

XX

Xy

XZ

2020

yo

yP

yQ

yR

yS

yT

yU

yV

yW

yX

yy

yZ

2024

Co

CP

CQ

CR

CS

CT

CU

CV

CW CX

Cy

CZ

P ro ductio n batch co des

ATEX Classification: 

II 2G Ex db IIC T6..(T5) Gb                -

10°C ≤ Ta ≤ +40°C(+50°C) 

 
Certificate reference: KEMA 09ATEX0024 X 
‘X’ Special conditions of safe use apply, see section 1.2.

 

ORIGINAL INSTRUCTIONS 

Refer to Declaration of 
Conformity for relevant 
Directives 
 

 

 

 

Отзывы: