In the Bridge Control MIB page, set the

parameters and then click on “Apply Changes”

to implement the settings.

Network Type -

 Set the operating mode of  the

Bridge. This field can be set to “Access Point”,

“Bridge Master” or “Bridge Slave”. (Default:

“Bridge Master”)

DS Channel -

 Set the channel number as the

operating radio channel.

Note:

The availiable channel settings are

displayed to the right of  the

“DS Channel” field. Local regulations

determine which channels are available.

FCC/IC: 1-11, ETSI: 1-13, France: 10-13,

Spain: 10-11, MKK: 1-14.
SSID -

 This should be set to the same value as

other wireless devices in your network. (Default:

“BRIDGE”)

Note:

The SSID is upper/lower case sensitive and

can consist of  up to 32 alphanumeric

characters.

RTS Threshold

 - Set the RTS Threshold to the

same as that used by other devices in your

network. (Default: 2,305, which means Disabled)

Содержание 2682W FICHE

Страница 1: ...hannel provides alternative wired LANs that can dramatically cut costs K Seamless connectivity to wired Ethernet LANs augments existing networks quickly and easily K Direct Sequence Spread Spectrum DSSS technology provides robust and secure wireless connection K Easy installation K Omni directional antenna TM SMC 2682W ...

Страница 2: ...nt or patent rights of SMC SMC reserves the right to change specifications at any time without notice Copyright 2001 by SMC Networks Inc Irvine California All rights reserved Printed in Taiwan Trademarks SMC is a registered trademark and EZ Connect and EZ Hub are trademarks of SMC Networks Inc Other product and company names are trademarks or registered trademarks of their respective holders Limit...

Страница 3: ...though they were on the same physical LAN The wireless bridge can also function as an Access Point and provide transparent wireless data communications between the wired LAN and or within the wireless Network and fixed portable or mobile devices equipped with a wireless adapter employing the same modulation This solution offers fast reliable wireless connectivity with considerable cost savings ove...

Страница 4: ... it Hardware Description Ethernet Compatibility SMC s EZ Connect Wireless Bridge can attach directly to 10BaseT Twisted Pair Ethernet LAN segments These segments must conform to IEEE 802 3 specification The Bridge appears as an Ethernet node and performs a routing function by moving packets from the wired LAN to remote workstations on the Wireless infrastructure Radio Characteristics The Wireless ...

Страница 5: ...shows exhibitions and construction sites which need temporary setup for a short time period Retailers airline and shipping companies which need additional workstations for a peak period Auditors who require workgroups at customer sites Access to databases for mobile workers Doctors nurses retailers or white collar workers who need access to databases while being mobile in a hospital retail store o...

Страница 6: ...Access Point be sure you can meet the following requirements An A C power outlet 100 240V 50 60Hz which will supply power for the access point An available RJ 45 UTP port on a 10BASE T Ethernet hub or switch 802 11 compliant wireless ethernet adapters with TCP IP compatible protocol installed Web Browser for configuration Power Wireless Activity Ethernet Activity Wireless Link Ethernet Link ...

Страница 7: ...efer to page 13 Normally the higher you place the antenna the better the performance 3 Connect the Ethernet Cable The SMC2682W can be wired to a 10 BASE T Ethernet with a network device such as a hub or a switch Connect into the RJ 45 connector socket on the back panel with category 3 4 or 5 UTP Ethernet cable and an RJ 45 connector 4 Connect the Power Cable Connect the power adapter cable to the ...

Страница 8: ...n Ethernet network using RJ 45 cable You may connect the SMC2682W to a network device such as a hub or switch Then run the utility program and configure the SMC2682W remotely as described below Windows NT 95 98 2000 ME Installation 1 Insert the SMC2682W utility disk into the floppy drive on your PC and then enter the following command A utility setup Follow the on screen instructions to install th...

Страница 9: ...ed on what it gathered from the network settings on your computer You may manually change it if you prefer some other settings or click OK if you d like to use the IP information the utility generated 4 A second box will pop up informing you that the IP address you ve assigned is only temporary Click OK and the utility will appear again listing the device again this time with IP information ...

Страница 10: ...e will appear as follows 6 Enter the password WLAN_BRIDGE and click Login This will take you to the home page 7 Click on Bridge Information MIB Bridge Control MIB TCP IP Settings or Change Password to select the page required The Bridge Information MIB screen displays the categories of information shown above ...

Страница 11: ...The availiable channel settings are displayed to the right of the DS Channel field Local regulations determine which channels are available FCC IC 1 11 ETSI 1 13 France 10 13 Spain 10 11 MKK 1 14 SSID This should be set to the same value as other wireless devices in your network Default BRIDGE Note The SSID is upper lower case sensitive and can consist of up to 32 alphanumeric characters RTS Thres...

Страница 12: ...erate the key elements with the internal algorithm according to the string defined in the Passphrase field The Manual Entry setting allows the user to manually enter key elements 2 Hexadecimal digitals in each block Passphrase The security key for WEP encryption is generated from your Passphrase string so it must be the same as all the other stations in your network 64 Bit Manual Entry Key 1 4 Eac...

Страница 13: ...reless Bridge by the network DHCP server If you do not have a DHCP server on the network you can either set them manually or use a temporary IP address any time you need to configure it If you want to set these yourself first set DHCP to OFF Then enter a new IP address and subnet mask in the New Settings section of the TCP IP Settings screen When finished click on Apply Changes ...

Страница 14: ...Password screen you may change the password on the Wireless Bridge A password is required to configure the SMC2682W Wireless Bridge We suggest changing your password from the default value to ensure network security ...

Страница 15: ...hoc for departmental or SOHO LANs Infrastructure for enterprise LANs Infrastructure for inter building LANs Network Topologies Ad Hoc Wireless LAN no AP or Bridge An ad hoc wireless LAN consists of a group of computers each equipped with a wireless adapter connected via radio signals as an independent wireless LAN Computers in a specific ad hoc wireless LAN must therefore be configured to the same...

Страница 16: ... can talk to any computer in its wireless group via a radio link or access other computers or network resources in the wired LAN infrastructure via the Access Point The infrastructure configuration not only extends the accessibility of wireless PCs to the wired LAN but also doubles the effective wireless transmission range for wireless PCs by passing their signal through one or more access points ...

Страница 17: ...ck with your administrator for the BSS ID of the Access Point or Bridge to which he wants you to connect A wireless infrastructure can also support roaming for mobile workers More than one Access Point can be configured to create an Extended Service Set ESS By placing the Access Points so that a continuous coverage area is created wireless users within this ESS can roam freely All SMC wireless net...

Страница 18: ...wo settings for the Wireless Bridge Bridge Master and Bridge Slave Bridges serving as local units are connected to the primary backbone infrastructure and are set to Bridge Master Those acting as remote Bridges attached to a remote backbone and communicating via radio to the local unit are set to Bridge Slave Point to Point Wireless Bridge The Point to Point Wireless configuration uses two Wireles...

Страница 19: ...e Master and each remote unit configured as a Bridge Slave Wireless Bridge with Wireless End Nodes A Wireless Bridge when functioning as a Bridge Master has the capability to serve the wireless client nodes within range The wireless client device can establish radio contact with the Wireless Bridge Master and have wireless access to all local and remote LANs workstations and network resources ...

Страница 20: ...om the SMC2682W Push in the reset button located on the back of the SMC2682W While holding in the button apply power to the Wireless Bridge Wait until both the wireless Activity LED and the wireless Link LED both start to flash on and off together about 5 seconds Release the Push Button and the LEDs will turn off You are now in the Control Mode Select the desired function by pressing the reset but...

Страница 21: ...es such as barrier composition and construction and local environmental interference that may impact your actual distances and cause you to experience distance thresholds far lower than those we post below If you have any questions or comments regarding the features or performance of this product or if you d like information regarding our full line wireless products you can visit us on the web of ...

Страница 22: ...ates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off an...

Страница 23: ...ites applicables aux appareils numériques de la classe B prescrites dens le Règlement sur le brouillage radioélectrique édicté par l Industrie CE Mark Declaration of Conformance This is to certify that this product complies with ISO IEC Guide 22 and EN45014 It conforms to the following specifications EMC EN55022 1988 CISPR 22 1985 Class B IEC 61000 4 2 2000 4kVCD 8kVAD IEC 61000 4 3 2000 3V m IEC ...

Страница 24: ...2 5 5 11 Mbps per channel Network Configuration Point to Point Point to Multi Point Operating Frequecy USA Canada 2 400 2 4835 GHz Europe ETSI 2 400 2 4835 GHz Japan 2 400 2 497 GHz Sensitivity 1 2 5 5 Mbps 80 dBm 11 Mbps 76 dBm typical Modulation CCK BPSK QPSK Power supply Input 100 240 AC 50 60 Hz Output 9 VDC 1A Output Power 13 dBm minimum Physical Size 5 12 x 7 09 x 1 58 in 13 x 18 x 4 cm Weig...

Страница 25: ...ows NT 2000 ME Temperature Operating 32 to 122ºF 0 to 50ºC Storage 32 to 158 F 0 to 70 C Humidity 5 to 8 non condensing Compliances CE Mark EN55022 Class B EN55024 IEC 61000 42 3 4 6 11 Emissions FCC Part 15 B ETS 300 328 RCR STD 33A Safety CSA NTRL CSA 22 2 No 950 UL 1950 EN60950 TÜV GS Vibration Shock Drop IEC 68 2 34 IEC 68 2 32 Standards IEEE 802 3 10BaseT IEEE 802 11b Warranty Limited Lifetim...

Страница 26: ...TURE OR ADVERTISING RESPONSE CALL U S A and Canada 800 SMC 4 YOU Fax 949 707 2460 Spain 34 93 477 4920 Fax 34 93 477 3774 UK 44 0 1189 748700 Fax 44 0 1189 748701 Southern Europe 33 1 41 18 68 68 Fax 33 1 41 18 68 69 Central E Europe 49 0 89 92861 200 Fax 49 0 89 92861 230 Nordic 46 8 564 33145 Fax 46 8 87 62 62 Middle East 971 48818410 Fax 971 48817993 South Africa 27 0 11 3936491 Fax 27 0 11 393...

Отзывы: