1.

 

General introduction 

Solar panel manufacturers stipulate that you must not walk or place concentrated loads 

on photovoltaic modules as incorrectly distributed weight may result in the formation 

of micro cracks in the solar cells. The damage ranges from a small loss of performance 

to the complete failure of individual modules. 

However,  there  is  an  increasing  amount  of  work  on  photovoltaic  arrays,  such  as 

servicing,  repairs  or  cleaning,  that  requires  you  to  walk  or  place  weight  on  the 

modules.  

The  SMB  SOLAR  MULTIBOARD  is  a  lightweight,  mobile,  non-slip  working 

platform that enables you to work on framed photovoltaic modules without damaging 

them. 

SMB  SOLAR  MULTIBOARDS  may  be  installed  on  the  solar  panels  only  for  the 

duration of the works and must be removed after the job has been completed. 

 

2.

 

Safety regulations 

 

When using the SMB SOLAR MULTIBOARDS you must comply with the general  

 

safety regulations for working on PV arrays and for working on scaffolding. The use  

 

of SMB SOLAR MULTIBOARDS does not exempt you from observing the following  

 

safety regulations: 

 

 

BGI 515 Personal protective equipment 

 

 

BGI 656 Safety when working on roofs 

 

 

BGI 659 Safety when cleaning buildings  

 

 

BGI 663 Handling of work and protective scaffolding 

 

 

Accident prevention regulations for winches, lifting and towing equipment 

 

 

Accident prevention regulations for first aid 

Содержание Solar Multiboard

Страница 1: ...ightweight mobile non slip working platform that enables you to work on framed photovoltaic modules without damaging them SMB SOLAR MULTIBOARDS may be installed on the solar panels only for the duration of the works and must be removed after the job has been completed 2 Safety regulations When using the SMB SOLAR MULTIBOARDS you must comply with the general safety regulations for working on PV arr...

Страница 2: ...the glass surface and the frame of the PV module The handle end must always be positioned facing downwards in the direction of slope i e towards the lower edge of the solar panel The board has an integrated handle for ease of use The clip end must always face upwards against the direction of slope i e towards the upper edge of the solar panel and be pushed into position figure 1 2 Make sure that t...

Страница 3: ...pper and lower frame of the PV modules to ensure that weight is distributed evenly and supported by the module frame and the substructure The boards must be laid in an offset pattern in the line of slope see figure 3 Figure 3 Correct alignment of SMB SOLAR MULTIBOARDS The SMB SOLAR MULTIBOARDS must not be laid across the mounting brackets of the modules Please also ensure that the boards are not p...

Страница 4: ...0 mm x 990 mm 990 mm 1020 mm 1 580 mm x 808 mm 1580 mm 1620 mm 1 580 mm x 808 mm 808 mm 900 mm SMB SOLAR MULTIBOARDS must not be subjected to sudden impacts no jumping or skipping Tools cleaning equipment etc on the glass surface of the modules or on the boards must not cause an obstruction to the service technician and must be secured against falling You are advised to wear knee pads to prevent i...

Страница 5: ...per and lower frame of each PV module figure 5 If an SMB SOLAR MULTIBOARD extends onto the next module below you must not place weight on this section figure 6 Figure 5 Correct position on SMB SOLAR MULTIBOARD Do not walk on this section Figure 6 Incorrect position on SMB SOLAR MULTIBOARD ...

Страница 6: ... placed on the lowest row of modules as described in point 3 Step on the SMB SOLAR MULTIBOARD and fit the second SMB SOLAR MULTIBOARD offset to One side Figure 7 Installation of SMB SOLAR MULTIBOARD Step onto the second SMB SOLAR MULTIBOARD and position the next SMB SOLAR MULTIBOARDS as described above Figure 8 Inserting the SMB SOLAR MULTIBOARD ...

Страница 7: ...board must be inspected to ensure that it is in proper working order before being used on framed PV modules This includes an inspection of the clip retainers and the backing layer and a general check for distortion of the board When cleaning PV arrays do not direct the jet of the high pressure washer at the backing layer on the contact surface as this may damage it When storing the SMB SOLAR MULTI...