SMARTSCAN 8K3 Series Скачать руководство пользователя страница 22

8K3 Series Cross-Beam Mute Accessories 

Installation Guide 

CD693/150120 

 

Smartscan Ltd 

19 

Appendix 2

 - Certifications 

 
 
Company 
 
 
 
 
 
 
 
 
 
Smartscan Limited has a certified quality assurance system in compliance with 
ISO 9001-2015. Certificate number FM27829. 
 
 
Products 
 
 
 
 
 
 
 
 
 
Smartscan safety light curtains are developed and manufactured in compliance 
with the European Machinery Directive 2006/42/EC and International Legislation 
and Standards. Smartscan products are Third Party approved by the Notified 
Body Safenet Limited, Notified Body number 1674.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

ISO9001 

FM27829

 

Содержание 8K3 Series

Страница 1: ...8K3 SERIES CROSS BEAM MUTING ACCESSORIES INSTALLATION GUIDE MACHINERY SAFETY SYSTEMS...

Страница 2: ...the 8K3 series mute accessories or any machine safety product The Installation Sheet and Installation Guide can be downloaded from our web site at www smartscan co uk The 8K3 series mute accessories...

Страница 3: ...UIREMENTS 8 ACTIVATE SWITCH ELECTRICAL CONNECTION 9 FIGURE H MUTING TIMER SEQUENCE 10 CROSS BEAM CONTROL TIMERS 10 FIGURE I IDENTIFICATION LABELS 11 FIGURE J TEST AND MAINTENANCE 12 TESTING THE MUTE A...

Страница 4: ...ll items for transit damage Match goods supplied to those specified on the delivery note Keep the Installation Sheet in a safe place Each 8K3 series mute accessory kit supplied would normally include...

Страница 5: ...ss Beam Mute Accessories Installation Guide CD693 150120 Smartscan Ltd 2 Figure B Dimensional Information The 8K3 Series T and L cross beam muting modules have the same cross section as the light curt...

Страница 6: ...n additional guard mounting point is required the bottom end cap bracket can be re fitted underneath the mute module housing Red LED s in the receiver Rx mute module are illuminated to show the mute b...

Страница 7: ...able for example where there is a limitation in the space available for mounting the modules In such cases external sensors that allow more flexibility are often used Polarised retro reflective sensor...

Страница 8: ...or fault finding Entry and Entry Exit T 087 008 Type 2 Inverted T shape cross beam muting at in feed zones or in situations where a pallet load may need to pass along the conveyor in both directions t...

Страница 9: ...tem that allows a period of 2 5 seconds between the pallet load clearing the mute sensors and clearing the light curtain beams If the 2 5 second period is exceeded the safety system will trip Note for...

Страница 10: ...receiver heads note distances for A and B Ensure that the pallet when entering and exiting the self muting safety light curtain system is central on the conveyor The distance for A and B to avoid tra...

Страница 11: ...not protect personnel from chemicals heat gases radiation flying parts etc as they are not a physical barrier The owner provider must carry out a Risk Assessment and provide machine operators instruct...

Страница 12: ...reset device should also be positioned so as not to be accessible from inside the danger area Activate Switch Electrical Connection Activate switch F7 Connect the red white wire in cable B to a normal...

Страница 13: ...a muted condition Following this timed period if the pallet load is still interrupting the mute beams or the safety light curtain beams the OSSDs will de energise thus initiating a stop condition Prov...

Страница 14: ...e Accessories Installation Guide CD693 150120 Smartscan Ltd 11 Figure I Identification Labels Examples are shown below of the identification labels that are affixed to the bottom of the transmitter TX...

Страница 15: ...by testing to check the system is still working correctly Regular function checking of the safety light curtain as well as at initial installation is required as part of the test and maintenance proce...

Страница 16: ...pe periodically Dust particles can be attracted to the Perspex window due to static charges This can be prevented by the use of an antistatic plastic cleaner and antistatic cloth Clean the windows wit...

Страница 17: ...aying particular attention to the information provided in Figures C E and I Refer to Fig J for test and maintenance procedures Every 24 hours carry out tests as indicated in Fig J Every 6 months check...

Страница 18: ...fault occurs that cannot be resolved or the equipment is damaged return the equipment to the nearest Smartscan distributor or Smartscan Ltd Indicate the nature of the fault and the symptoms displayed...

Страница 19: ...8K3 Series Cross Beam Mute Accessories Installation Guide CD693 150120 Smartscan Ltd 16 Figure M Declaration of Conformity...

Страница 20: ...8K3 Series Cross Beam Mute Accessories Installation Guide CD693 150120 Smartscan Ltd 17 Figure N Glossary of Words and Language Translation...

Страница 21: ...light curtain is only one element in the overall machine safety circuit the whole machine safety control circuit must be a fail safe design The stopping elements of the machine should be regularly che...

Страница 22: ...ce system in compliance with ISO 9001 2015 Certificate number FM27829 Products Smartscan safety light curtains are developed and manufactured in compliance with the European Machinery Directive 2006 4...

Страница 23: ..._______________________________________________ _________________________________________________________________ _________________________________________________________________ ____________________...

Отзывы: