SMARTSCAN 5K8 SERIES LIGHT CURTAIN
9
CD401/130711
INSTALLATION SHEET EXPLAINED
Please note that the Installation Sheet Explained documents are periodically updated. The product Installation Sheets
supplied with the product should be referenced first for current installation information.
Activate (F13) -
A push button or key switch is required, having a N/O switch
contact. Connect the blue (BU) wire from the user cable (B) to one side of the
switch and the other side of the switch to L- (0v dc).
Manual Restart - Turning the ‘activate’ switch to ON and then releasing the
switch will automatically turn on the safety outputs (F1), providing the light
curtain is clear of obstruction.
(RX) Light curtain ‘clear’ indicator (F14) -
A green LED indicator mounted on
the receiver unit illuminates when the light curtain is clear of obstruction.
Mute ‘clear’ indicators M1 (F15) and M2 (F16) -
Amber LED indicators
mounted on the receiver unit extinguish independently, when mute sensors M1
and M2 are blocked.
(RX) Light curtain ‘block’ indicator (F17) -
A red LED indicator mounted on
the receiver unit illuminates when the light curtain is obstructed.
Safe output ‘on’ (F18) -
A green LED indicator mounted on the receiver unit
illuminates when the signal output switching relays are ON.
Safe output ‘off’ (F19) -
A red LED indicator mounted on the receiver unit
illuminates when the signal output switching relays are OFF.
Status output indicator – (F20) –
An amber LED indicator mounted on the
receiver unit is illuminated when the status relay is de-energised, but
extinguishes when the status relay is on.
Mute condition ‘On’ indicator (F21) -
Amber LED indicator mounted on the
receiver unit illuminates when the light curtain output relays are in a muted
condition.
(TX) transmitter diode on indicators – (F22)
. A red LED corresponding to
each transmitter diode is illuminated when each transmitter is operational.
Activate ‘On’ indicator – (F23)
. A red LED mounted on the receiver unit to
indicate reset switch activation.
EDM ‘On’ indicator – (F24)
. A red LED mounted on the receiver unit
illuminates when an EDM signal is present.
Mute Enable (ME) ‘On’ indicator – (F25)
. A red LED mounted on the receiver
unit illuminates when a mute enable (conveyor run) signal is present.