POS Guardian

Power Cord

Installation for Protection for Telephone Line and Network Cable

Installation for Protection for Network Cable

TELEPHONE

1. Unplug  the equipment's telephone cable from the wall jack and plug into the RJ11 "DEVICE" 
    on the 

POS Guardian

.

2. Plug the provided telephone cable to the RJ11 jack  "LINE" on the 

POS Guardian

.

3. Plug the other end of the telephone cable into the RJ11 wall jack.

CAUTION

: - Never install telephone wiring during a lightning storm.

                  - Disconnect telephone line at the network interface before installing the secondary
                    protector.
                  - Intended for indoor use only.

Use the Standard CAT 5 Network Patch cord when using the Network protection RJ45 circuit.

Connected

Equipment with 

Tel./Modem Jack

Power Cord

Power Cord

Phone Cord

Phone Cord

Network Cord

Network Cord

LINE

LINE

DEVICE

DEVICE

Phone 

Wall Jack

Network Jack/ HUB

Connected

Equipment with 

Network Jack

IMPORTANT: The POS Guardian is designed to be compatible with a GFCI (Ground Fault 
Circuit Interrupter), however, during plug in the GFCI might trip. Press the reset button to 
restart the circuit.  
Note: Do Not plug more than 3 POS Guardian products to a circuit that has a GFCI circuit 
breaker or GFCI wall outlets. 

NOTE

: Model TBF15P-1111TN comes 

with security straps, warning label and 
Velcro™ to secure unit to connected 
equipment. 

STRAP FOR PIGTAIL 

RECEPTACLE

The label on the security strap is permanent 

and warning: to unplug the unit will cause the 

label to tear out and void the warranty.

IMPORTANT: Velcro™ strips are provided so the 

POS Guardian 

can be attached to your equipment 

when needed. Do not place Velcro™ over label.

BACK OF UNIT

Provided with

Velcro™ strips

                                        The RED light indicates over voltage, improper ground connection or reversed power 
                                        wires which needs to be corrected. In an over voltage incident, power is disconnected 
                                        to protect the connected equipment. 

IMPORTANT

: If the RED Light comes on, contact your electrician to inspect and correct the outlet wiring in 

order to receive the maximum protection for your connected equipment.

The green light confirms properly the connected equipment is fully protected. 

GREEN LIGHT - 

RED LIGHT - 

NETWORK

1. Unplug the equipment's network cable from the wall RJ45 network jack and plug into the RJ45 
    "DEVICE" on the 

POS Guardian

.

2. Plug the provided CAT5 cable to the RJ45 jack "LINE" on the 

POS Guardian

.

3. Plug the other end of the CAT5 cable into the wall RJ45 network jack. Your equipment is now 
    fully protected. Place the 

POS Guardian

 where monitoring lights can be observed.  

Telephone Line Protection clamping voltage 250-350 vdc.

Содержание POS GUARDIAN

Страница 1: ...o developing and manufacturing the highest performance power protection and filtration devices for your electronic equipment Proper use of this device will provide the protection needed for your connectedequipment SMART GROUND 16005530 Rev 111 14 POS GUARDIAN ELECTRONIC POWER CONDITIONER Equipped with WITH SMART GROUND ...

Страница 2: ...all this device if there is not at least 10 meters 30 feet or more of wire between the electrical outlet and the electrical service panel Risk of Electric Shock Do not plug into another relocatable power tap FEATURES If you have any questions call us at our Tech Support line toll free 1 800 772 7633 or email us at support smartpowersystems com DESCRIPTION MODEL PART NUMBER 120V 15A two 5 15R outle...

Страница 3: ... GFCI wall outlets NOTE Model TBF15P 1111TN comes with security straps warning label and Velcro to secure unit to connected equipment STRAP FOR PIGTAIL RECEPTACLE The label on the security strap is permanent and warning to unplug the unit will cause the label to tear out and void the warranty IMPORTANT Velcro strips are provided so the POS Guardian can be attached to your equipment when needed Do ...

Страница 4: ...ed LISTED LINE CONDITIONERS Reduces the need for a dedicated line where voltage on ground is present This transformer isolation technology is an option to expensive rewiring where poor wiring conditions exist on older or renovated buildings AUTOMATIC VOLTAGE REGULATOR AVR SERIES Regulates the voltage to protect equipment against voltage sags and brownouts Electronic systems are designed to operate...

Отзывы: