9
Fault Code 3
Drum Stalled.
Remedy:
(1) If there is mechanical movement of the drum, but this fault
code is appearing, follow the procedures for fault code 2.
(2) If there is no mechanical movement of the drum, check drum
movement mechanisms: belt, motor and motor harness.
(3) Replace the motor control module.
(4) Replace the motor.
Fault Code 4
Invalid Option Link Read.
The motor control module heat source option link read is invalid.
Remedy:
Replace the motor control module.
Fault Code 6
Door Jammed - User Warning.
The door is unable to close due to either clothes catching or an excessive
closing load.
Remedy:
(1) Remove the obstruction.
(2) Reposition or remove some of the load.
(3) Fix the cause of binding in the door closing mechanism.