DRYER
MODELS
DEGX1 and DGGX1
517772
Fisher & Paykel Appliances © 2004
August 2004
Страница 1: ...DRYER MODELS DEGX1 and DGGX1 517772 Fisher Paykel Appliances 2004 August 2004...
Страница 2: ...32V Valve Regulator Gas Combination gas pressure regulator and dual automatic gas valve Voltage Rated 120 Volts AC 60 Hz Resistance Across Terminals 1 2 1 4 kOhms 1 3 560 Ohms 3 4 1 3 kOhms Orifice 43...
Страница 3: ...Volts between two phases Thermostat Cutout Automatic Reset Electrical Type SPST Trip Temperature 158 F 37 70 C 3 Reset Temperature 131 F 39 55 C 4 Thermostat Cutout Manual Reset Electrical Type SPST...
Страница 4: ...60 C 127 F 53 C When tumbling the heat source is turned on as shown in the table below Electric Door Close Direction 4 minutes Door Open Direction 40 seconds Element 2 3 Heat Element 1 3 Heat Element...
Страница 5: ...aults will manifest when the user attempts to run the dryer again However at any time the Last Fault can be recalled from memory Diagnostic Mode Entering the Diagnostic Mode a Turn the power supply to...
Страница 6: ...gnostic mode press any cycle button Entering the Data Download Mode a Turn the power supply to the dryer on b Press and hold the Auto Dry down button then press the Power button This enters the diagno...
Страница 7: ...ee Detailed Fault Codes page 8 at the same time as sounding a user warning Pressing any button will stop the sound and pressing the Start or Power buttons or the completion of the cycle will stop the...
Страница 8: ...ons failure between the sensor module and motor control module Remedy 1 Check the continuity of the module interconnecting harness 2 Replace the sensor module 3 Replace the motor control module Fault...
Страница 9: ...lace the motor control module 4 Replace the motor Fault Code 4 Invalid Option Link Read The motor control module heat source option link read is invalid Remedy Replace the motor control module Fault C...
Страница 10: ...hecking particularly for short circuits Approximate resistances 10 at various temperatures are 32 F 0 C 33 KOhms 72 F 22 C 11 KOhms 104 F 40 C 5 KOhms Replace thermistor and harness if out of range 2...
Страница 11: ...il If there is continuity through these replace the sensor module Fault Code 12 Lid Lock Switching Device Failure Remedy Check that there are no short circuits in the lid lock circuit which may have c...
Страница 12: ...ting good airflow 3 Ensure that there is nothing inhibiting unrestricted airflow through the heater housing through the drum lint filter lint collector and through the exhaust duct and that the elemen...
Страница 13: ...sembly of the top deck to the cabinet front 4 Ensure the user intervention tab is not inhibiting door grabber movement 5 Check that the actuator linkage is located correctly There must be no gap betwe...
Страница 14: ...ge The door actuator movement was interrupted by low voltage brown out Remedy 1 Ensure mains voltage is within 10 and 15 of nominal 2 Replace the sensor module as voltage measurement circuit may be re...
Страница 15: ...d on replace the sensor module 2 Replace the motor control module Fault Code 30 Lid Lock unable to Lock User Warning The lid lock failed to lock Not user displayed Remedy 1 Ensure the lid is closed an...