background image

34

Setting the Heart Beat mode:

If  this  mode  is  (ON),  which  is  the  factory  setting,  the  step  counter  will  try  to 
communicate  every  minute  with  receivng  device.  Is  there  any  receiving  device  in 
reach which supports this function, the step counter will be set automatically. After 
the step counter was set, the heart beat function will start again every 30 minutes.

The benfit of this function is to update the setting automatically. Another benefit 
is that the step counter sends the battery status to the receiving device. This way 
the receiving device can warn the user that the battery is almost empty. You can see 
Heart Beat in picture 6. Switch the mode (ON) or (OFF) by using the “M/

” button. 

pict. 6

Содержание Walk P+

Страница 1: ...23 ENGLISH HMM Diagnostics GmbH D 69221 Dossenheim Germany www hmm info Please read this user manual thoroughly before first using this device 3 D Step counter with wireless data transfer User Manual...

Страница 2: ...s 27 Inserting the battery 27 Mounting the carrying cord 28 Before first use 29 Setting weight step length signal tone und time 29 Manually transfer Not Sent data 35 Manually transfer all data 36 Star...

Страница 3: ...p counter has an integrated ANT module making it possible to transfer the measured data steps calories distance to an accordant receiving device like PC laptop hFon plus or the hFon collect smartLAB w...

Страница 4: ...Battery 1 x CR 2032 battery 5 Unit for steps walked amount 6 Unit for calories kcal 7 Unit for distance km 8 Unit weight kg lb adjustable 9 Communication data transfer ANT Key Lock Symbol Mute Symbol...

Страница 5: ...ttery lid on the back of the device Place the coin cell with the plus side to top into the opening If you change the battery use the screwdriver to lever off the battery Afterwards put the lid back on...

Страница 6: ...he cord to the device by doing the following steps Push the thin end of the cord through the two tiny eyes at the back side of the device Pushing together the cord a little bit makes it easier to sque...

Страница 7: ...ay there is no need to setup the step counter manually Please refer to Heart Beat section for more details Setting weight step length signal tone und time Setting weight 1 Press the M button and choos...

Страница 8: ...confirm Setting step length After you entered your body weight the step length symbol flashes Now you can enter your step length by pressing the M button The step length can vary between 30 and 120 c...

Страница 9: ...rs by pushing the M button Confirm by pushing Disp Set Afterwards you can set the minutes by repeating the steps mentioned Finally confirm again with the Disp Set button Note Setting your weight and s...

Страница 10: ...be set correctly Otherwise measured data can not be assigned accordingly ANT settings ANT is a wireless data transfer standard In order to use it transmitting and receiving device must be equipped wit...

Страница 11: ...l be sent out every 10 minutes to the accordant receiving device All data which was stored during the last time interval will be sent out then You can see the automatic mode in picture 5 Switch the mo...

Страница 12: ...ll be set automatically After the step counter was set the heart beat function will start again every 30 minutes The benfit of this function is to update the setting automatically Another benefit is t...

Страница 13: ...In the upper display area SEnd appears If you now press M the display will show picture 7 By pressing Disp Set again you will manually trigger the data which has not been sent yet transfer The symbol...

Страница 14: ...nds In the upper display area SEnd appears If you now press M twice the display will show picture 8 By pressing Disp Set again you will manually trigger the all data transfer The symbol for wireless d...

Страница 15: ...37 ENGLISH pict 09 pict 10 pict 11...

Страница 16: ...ou have walked so far you need to turn on the Display Press on the Disp Set button to unlock the Display It will then turn on After physical exercise or long walks simply press Disp Set to view your t...

Страница 17: ...et after the time setting was set back to 0 00 Additional functions Battery display When the low battery symbol appears in the display your smartLAB walk P needs new batteries Please exchange the batt...

Страница 18: ...minutes of non use To turn it back on click on the Disp Set button Maintenance Do not dump the device or use force while operating it Avoid exposing the device to high temperatures or direct sunlight...

Страница 19: ...he specification of EN Standards EN 60950 1 2006 A11 2009 A1 2010 A12 2011 WEEE note The WEEE Waste Electrical and Electronic Equipment Directive that came into effect as European law on 13th February...

Страница 20: ...responsibility to deliver all the disused electri cal and electronic equipment to the respective collection points A separate collection and proper recycling of electronic waste helps dealing economic...

Страница 21: ...on HMM Diagnostics GmbH gives a 2 year warranty by purchasing this smartLAB product You can even extend the warranty from 3 to 5 years without extra pay when you register your product Please register...

Страница 22: ...cs GmbH Friedrichstr 89 D 69221 Dossenheim Germany E mail info hmm info www hmm info Hersteller Manufacturer Weitere Informationen zu den smartLAB Produkten More information on our smartLAB products w...

Отзывы: