6. The green "Probe" indicator will begin to flash indicating that the IR Linc is

ready to receive PLC commands to associate with the learned IR signal.

7. From a compatible transmitter, send the house/unit code that is to be identi-

fied with this IR signal followed by the function code (ON, OFF, Dim, etc.).

8. The green indicator will turn on solid for a few seconds to indicate that it suc-

cessfully received the PLC commands then turn off.

Learning Tips:

• The remote should be level with the

IR Linc and directly in front on it.

The emitter on the front of the

remote should be located directly

between the two built-in IR blasters

on the front of the IR Linc and locat-

ed about 1 to 2 inches from them.

• The remote should have fresh strong batteries.  If commands are not being

learned correctly or it takes multiple tries, try changing the batteries.

• Since the green "Probe" indicator is used to indicate status during learning

cycles, the probe be disconnected during learning.

• The IR learning time is fixed at no more than five seconds.  IR Linc will allow 15

seconds for the capturing the associated powerline signal.

• Sunlight, florescent light sources and plasma screen monitors can interfere with

IR reception.  The best learning will occur in darkened rooms.

• The length of time the teaching remote's button is held down can have an effect

on learning success.  In some cases, the button may need to be held down

longer than normal for the IR Linc to successfully sample the signal.  Other

times, it may only need to be held down less than a second.

Errors that can occur during learning

If powerline commands are sent while the green "Probe"
indicator is blinking and the green indicator turns off
instead of going solid, the IR command was not learned
properly.  The command was not saved to memory and
no deleting is necessary.  Re-teach the IR command by
following the instructions above.  Sending a powerline
command during the IR learning cycle will take the IR
Link out of the learning mode.
The IR Linc has a finite amount of memory for learning IR commands.  The total
number of commands it can learn is based upon the length of each IR command.  A
maximum of 31 IR commands can be learned, assuming that the sum of each com-
mand does not exceed the IR Linc Controller's memory.  If the green "Probe" indica-
tor goes solid and then turns off instead of blinking after the command is learned,
the memory is full.

7

Tip:

Unplug or disable other
PLC/ X10 transmitters in
the house during program-
ming.  This will reduce the
likelihood of an uninten-
tional signal being learned
by the IR Linc.

Содержание 1623 IR Linc

Страница 1: ...IR LincTM Control Audio Video equipment with X10 PLC signals in you home Model 1623 IR Linc ...

Страница 2: ... retained after a power outage Small sized Other Complementary Smarthome Products Your IR Linc is ready to be used by most any powerline based product on the mar ket However when teamed up and used with other Smarthome automation prod ucts you can transform the whole home s automation system to the same level and sophistication normally found in multi million dollar homes PC to IR LincTM Control y...

Страница 3: ...o ciate with the learned IR signal 4 Send the PLC signal The green indicator will turn on solid then off See page 6 for more detailed instructions Overview The Active indicator will show that the unit is ready to learn IR signals During normal use it will blink when IR signals are transmitted The two IR Learn blast emitters emit IR light to control the AV devices During programming they sense the ...

Страница 4: ...6 This probe can be attached to any device that generates a 3 28 volt AC or DC signal Some AV equipment have low voltage outputs that may be used to detect the device s power sta tus Detects the presence of a baseband video sig nal when connected to the VIDEO OUT jack Can t be used with video gear that outputs a blank or blue screen when switched off or in stand by Contact Closure Probe 8018 Extra...

Страница 5: ...ent status The IR Linc can be programmed in one location and then transported to its final location without losing the stored data 4 Be careful plugging in external emitters on the rear of the unit If an emitter is plugged into the Probe jack it will be instantly destroyed 5 When using stick on emitters it is important that to find the IR sensor on the equipment and place the emitter directly over...

Страница 6: ...ontinuous control functions like volume up or channel up The IR command will be sent as long as the BRIGHT command is being received DIM IR command is for continuous control function such as volume down or channel down The IR command will be sent as long as the DIM command is being received House Unit Code repeated Normal IR Only one IR command will be sent upon receipt of the powerline signal To ...

Страница 7: ...e with IR reception The best learning will occur in darkened rooms The length of time the teaching remote s button is held down can have an effect on learning success In some cases the button may need to be held down longer than normal for the IR Linc to successfully sample the signal Other times it may only need to be held down less than a second Errors that can occur during learning If powerline...

Страница 8: ...y difference is that in step 7 the PLC command sent is the same for all the IR commands Multiple IR signals can also be learned to the PLC commands that check probe sta tus The IR Linc will send out the multiple IR commands as it would under a normal command except that its checks the probe status before it sends out each IR com mand If the probe status changes while it is going through the macro ...

Страница 9: ... addresses and IR signals learned 1 Press and hold the SET button for five seconds until the green Probe indicator comes on 2 The green indicator will remain lit for a few sec onds then it will turn off 3 When the indicator turns off the master reset Tip A reset should only be done if the learning processed is going to restarted There is no way of retrieving IR commands or undoing a factory reset ...

Страница 10: ...ike those found outside of North America It can t be used on 230 volt electrical systems even with a step down trans former A voltage converting transformer will block powerline signals The PowerLinc II adapter which contains special circuitry the IR Linc box needs is not substitutable with other powerline interfaces Sometimes the signals from the built in blaster don t trigger the AV device Using...

Страница 11: ...ase visit a retailer or distributor for the complete line of automation products from Smarthome Design KeypadLinc 6 with 450W integrated dimmer Specifications Number of IR Commands 31 Memory Volatility EEPROM non volatile memory Input Power 12 Volts DC supplied by PowerLinc Interface Dimensions 4 0in wide 2 5in deep 1 1in high Weight 2 pounds Emitters 2 built in blast and up to three external emit...

Страница 12: ...eive an RA return authorization number properly package the product with the RA clearly printed on the outside of the package and send the product along with all other required materials to Smarthome ATTN Receiving Dept 16542 Millikan Ave Irvine CA 92606 5027 Limitations THE ABOVE WARRANTY IS IN LIEU OF AND SMARTHOME DISCLAIMS ALL OTHER WARRANTIES WHETHER ORAL OR WRITTEN EXPRESS OR IMPLIED INCLUDI...

Отзывы: