User Guide STU2161407M-L 

7

 

 

3. Digital Inputs 

When the input is not connected, it is assumed level 

H

.  

 

Resistance for input must be less than 1200 Ohm. 

4. Analog Inputs 

Input can withstand for a short time higher voltages. The only limitation is heat 
over the resistance.

 

When an input is set in the current mode, is a normal 

resistance of the input slightly to heat up. 
 

With jumper removed, the input is in the Voltage mode, when placed jumper – Current mode. 
 

To select mode: 

1.

 

Set Jumper 

2.

 

Select MODE from Software 

 

Input X

Rin=91k

R

s

h=

50

0

JpAX

GND

 

Uses 10-bit ADC. Result is 0 – 1023(0x3FF). 

Voltage mode

:  

The range is 0 – 10.23 V. 

Step = 0.01V

. Rin = 91k. 

Current mode

 The range is 0 – 20.46 mA. 

Step = 0.02mA

. Rsh = 500 ohms. 

 

4. Outputs 1- 8 

Outputs are implemented with relays SUN RAS-0515, 10A/250V. 

5. Outputs 9- 16 

Outputs are implemented with optocouplers LTV847. Current through the LED 

is 5 mA. 
 

All inputs and outputs are independent

 

 

Содержание STU2161407M-L

Страница 1: ...SmartHardware User Guide STU2161407M L 1 STU2161407M L USB programmable controller Ver 1 2 2013 Software ver 1 1 2013 ...

Страница 2: ... bytes User Data RAM 4 bytes Outputs 8 RELAYS 5V 250V 10A 8 With Optocouplers I 15mA V 30V Digital Inputs 14 0 50 V I input 250uA Analog Inputs 7 10bit ADC 0 10 V Rin 91k step 0 01 V 0 20 mA Rsh 500 step 0 02 mA Power Supply Single or Double Con0 5V Icc max 60mA Con1 5V Con2 5V Con3 5V 0 56A Dimensions 162 x 80 x 20 mm Dimensions for installation 152 x 70 mm Weight 172 gr PC Software STU2XXXX Assi...

Страница 3: ...SmartHardware User Guide STU2161407M L 3 ...

Страница 4: ...SmartHardware User Guide STU2161407M L 4 ...

Страница 5: ...SmartHardware User Guide STU2161407M L 5 ...

Страница 6: ... can be powered with single or dual power supply for logic Usually using one of Con1 or Con2 for power and Con0 only is used for programming by computer Con3 is used only for Outputs with Relays This is a block diagram of power Backup Battery is used only in HID Device mode The controller can operate without it if it is not needed in both modes ...

Страница 7: ...lightly to heat up With jumper removed the input is in the Voltage mode when placed jumper Current mode To select mode 1 Set Jumper 2 Select MODE from Software Input X Rin 91k Rs h 500 JpAX GND Uses 10 bit ADC Result is 0 1023 0x3FF Voltage mode The range is 0 10 23 V Step 0 01V Rin 91k Current mode The range is 0 20 46 mA Step 0 02mA Rsh 500 ohms 4 Outputs 1 8 Outputs are implemented with relays ...

Страница 8: ...eatures This controller can operate in two modes HID Device Mode jumper removed and COM Port Mode jumper placed Programming in both modes is independent Jumper checked only at power on Please see USER GUIDE for PC software STU2XXXX Assistant for other features HID Device Mode ...

Страница 9: ...SmartHardware User Guide STU2161407M L 9 COM PORT Mode ...

Страница 10: ...SmartHardware User Guide STU2161407M L 10 Thank you for using our products For current versions and new products seek us at www SmartHardware eu ...

Отзывы: