HRC200 Industrial Remote Control User Manual Page 8 of 16
4.2
HRC200M RECEIVER PANEL INDICATORS AND INTERNAL KEYS
Fig.2 Receiver Panel Description
Table 5 Indicators and Keys Description
Indicator
Description
POWER
(Indicator: green)
Always illuminating: power is normal;
Always extinguishing: power is abnormal.
RS485
(Indicator: green)
Flashing: RS485 communication is normal;
Always extinguishing: RS485 communication fails.
LoRa (Indicator: green)
Flashing: communication with remote control is normal;
Always extinguishing: communication with remote control fails.
PAIR (key)
Long press it 6s to enter pairing mode;
Press it again after entering pairing mode can cancel pair.
4.3
COMMUNICATION CHANNEL CONFIGURATION
The remote control configures the communication channel via jumper cap. Jumper cap leftmost
and rightmost positions are inactive, it is 1 when the middle four positions are connected to the jumper
cap, otherwise it is 0. The default jumper cap position is 1111 (515MHz).
Fig.3 Communication Channel Configuration