Smartgen CMM366B-4G Скачать руководство пользователя страница 4

       

CMM366B-4G/CAN-4G Cloud Monitoring Communication Module User Manual 

CMM366B-4G/CAN-4G Cloud Monitoring Communication Module    2020-03-10 Version 1.0 Page 4 of 19

 

1  OVERVIEW 

CMM366B-4G/CMM366CAN-4G

  Cloud  Monitoring  Communication  Module  is  4G  wireless  network 

communication protocol switching module of global network communication, which can achieve genset 

(with SCI) connection with Internet. After logging into cloud server, module will receive corresponding 

genset  controller  communication  protocol  from  cloud  server.  Cloud  server  module  can  obtain  genset 

data  information  via  RS485,  USB,  LINK,  CAN,  or  RS232,  and  send  the  information  to  related  could 

server via 4G wireless network. Users can at real time monitor genset running status and check genset 

running records by mobile APP (IOS or Android), or PC etc. terminal device.   

It not only can realize genset monitoring, but also can be connected with some digital alarm inputs, to 

realize monitoring of genset entrance guard, prevention of burglary, fire control etc. ancillary facilities.   

It  has  GPS  positioning  function,  which  can  upload  the  obtained  longitude  and  latitude,  altitude 

information at real time to the corresponding cloud server.   

CMM366CAN-4G cloud monitoring communication module has CAN port, but CMM366B-4G hasn't. 

Except for this, these two cloud monitoring communication modules has same functions.   

2  PERFORMANCE AND CHARACTERISTICS 

 

Connected to cloud server via 4G wireless network, one cloud monitoring module for one genset; 

 

Multiple communicating ports with genset control module: RS485, RS232, LINK, CAN, USB (Host); 

which can monitor most genset control modules of leading brands internationally;   

 

Wide power supply: DC (8~35)V, which can directly use genset build-in start battery;   

 

With ARM-based 32-bit SCM, high integration of system and strong programming ability;   

 

GPS positioning function to obtain genset location information, to realize genset location;

 

 

 

Applying network data communication protocol of Json format, upload the genset data changes at 

real time, meanwhile compression algorithm is applied, which extremely reduces network flow;   

 

Immediately upload the data to cloud server when genset alarms occur;   

 

Event log memory function, which can ensure data won't get lost when network is not steady;   

 

Cloud Modem can be upgraded by 4G signal, convenient for module' s maintenance;   

 

2 configurable digital input ports, which can be connected with external alarm signals;   

 

Module panel has power and multiple communication status indicators; clear for watching module 

working status;   

 

Lamp test function;   

 

Parameter setting function: users can do parameter setting by module USB port;   

 

Applying  standard 

π-type  35mm  guide-rail installation  or  screw-fixed  installation,  and  the module 

can be installed in the genset control box;   

 

Modular structure design, flame retardant ABS enclosure, light weight, compact structure with easy 

installation.     

Содержание CMM366B-4G

Страница 1: ...CMM366B 4G CMM366CAN 4G CLOUD MONITORING COMMUNICATION MODULE USER MANUAL SMARTGEN ZHENGZHOU TECHNOLOGY CO LTD ...

Страница 2: ...any material form including photocopying or storing in any medium by electronic means or other without the written permission of the copyright holder Applications for the copyright holder s written permission to reproduce any part of this publication should be addressed to SmartGen Technology at the address above Any reference to trademarked product names used within this publication is owned by t...

Страница 3: ... PANEL INDICATOR AND BUTTONS 5 4 2 GPRS 4G ANTENNA PORT 7 4 3 GPS ANTENNA PORT 7 4 4 SIM INSTALLATION 7 4 5 RS485 PORT 8 4 6 RS232 PORT 8 4 7 LINK PORT 8 4 8 USB HOST 9 4 9 USB DEVICE 9 4 10 CAN PORT 10 4 11 TERMINALS 10 5 PROGRAMMABLE PARAMETERS 11 5 1 CONTENTS AND SCOPES OF PARAMETERS 11 5 2 PC CONFIGURATION INTERFACE 12 6 SYSTEM DIAGRAM 13 7 CASE DIMENSION AND INSTALLATION 13 8 APP INSTALLATION...

Страница 4: ...has same functions 2 PERFORMANCE AND CHARACTERISTICS Connected to cloud server via 4G wireless network one cloud monitoring module for one genset Multiple communicating ports with genset control module RS485 RS232 LINK CAN USB Host which can monitor most genset control modules of leading brands internationally Wide power supply DC 8 35 V which can directly use genset build in start battery With AR...

Страница 5: ...e USB female port RS485 Isolated type RS232 General type LINK SmartGen exclusive port USB Device B type USB female port CAN Port Isolated type GPRS Port Standard SMA port female SMA port male for antenna GPS Port Standard SMA port female SMA port male for antenna active antenna Wireless Network LTE TDD LTE FDD HSPA TD SCDMA EVDO GSM GPRS EDGE Case Dimensions 72 5mmx105mmx34mm Working Conditions Te...

Страница 6: ...sabled Normally Light On GPS not gained satellite signal Flash GPS gained satellite signal RS232 LINK Red Normally Light Off RS232 LINK Disabled Normally Light On Communication failed Flash Communication normal CAN Red Normally Light Off CAN disabled Normally Light On Communication failed Flash Communication normal GPRS 4G Red Light Off 4G module login with server unsuccessfully Light On Login wit...

Страница 7: ...e or cannot be gained Antenna port 50Ω SMA female active antenna Fig 2 CMM366B 4G CMM366CAN 4G Antenna Connection NOTE GPRS antenna and GPS antenna cannot be connected reversely 4 4 SIM INSTALLATION Insert 4G SIM card CMM366B 4G CMM366CAN 4G will connect to server via wireless mobile network NOTE This module supports 4G wireless network of global network communication Standard SIM card is applied ...

Страница 8: ...module RS485 port with Genset Controller RS485 port 120Ω terminal resistor is recommonded and short connect RS485 A and TR terminal Fig 4 RS485 Connection 4 6 RS232 PORT Receive genset data information by connecting module RS232 port with Genset Controller RS232 port Fig 5 RS232 Connection 4 7 LINK PORT Receive genset data information by connecting module LINK port with Genset Controller LINK port...

Страница 9: ... 19 4 8 USB HOST Receive genset data information by connecting module A type USB port female with Genset Controller USB port via USB cable Fig 7 USB Host Connection 4 9 USB DEVICE All the parameters can be configured and view CMM366B 4G CMM366CAN 4G ID Login password by connecting USB port with PC Fig 8 USB Connect PC Device Fig 9 USB Connect SGB100 Module ...

Страница 10: ...minals Description No Function Cable Size Note 1 B 1 0mm2 Connected with negative of starter battery 2 B 1 0mm2 Connected with positive of starter battery 3A fuse is recommended 3 Digital Input 1 1 0mm2 Active when connect to B 4 Digital Input 2 1 0mm2 Active when connect to B 5 CANL 0 5mm2 Impedance 120Ω terminal resistor is recommended short connect CHAH and TR terminal 6 CANH 0 5mm2 7 TR 0 5mm2...

Страница 11: ...on 2 Longitude 180 180 113 554879 GPS location altitude information 3 Latitude 90 90 34 802335 4 Altitude 9999 9 9999 9 m 100 0 Digital Inputs Digital Input 1 1 Setting 0 9 0 Default Not used 2 Type 0 1 0 0 Active when close 1 Active when open See Table 6 Digital Input Ports Content 3 Delay 0 20 0 0 0 Action delay Digital Input 2 1 Setting 0 9 1 Default Lamp test 2 Type 0 1 0 0 Active when close 1...

Страница 12: ... is prohibited when input is active 3 Access Alarm Input Access alarm is uploaded to server when input is active 4 Fire Alarm Input Fire alarm is uploaded to server when input is active 5 Alarm Input External alarm is uploaded to server when input is active 6 Reserved 7 Reserved 8 Reserved 9 Factory Test Mode It is only used for factory test when active 5 2 PC CONFIGURATION INTERFACE Connecting th...

Страница 13: ...ne CMM366B 4G CMM366CAN 4G module connects with one genset monitor module It can be connected via RS485 port LINK port CAN port RS232 port or USB port Fig 13 CMM366B 4G CMM366CAN 4G System Diagram 7 CASE DIMENSION AND INSTALLATION 35mm guide rail installation or screw fixed M4 installation can be applied Case dimensions are as below Fig 14 CMM366B 4G CMM366CAN 4G Case Dimension ...

Страница 14: ...ng Communication Module User Manual CMM366B 4G CAN 4G Cloud Monitoring Communication Module 2020 03 10 Version 1 0 Page 14 of 19 Fig 15 CMM366B 4G CMM366CAN 4G Guide Rail Installation Fig 16 CMM366B 4G CMM366CAN 4G Screw Installation ...

Страница 15: ... 1 Scan the QR code on the enclosure of CMM366B 4G CMM366CAN 4G cloud monitoring communication module QR code is as Fig 17 download the APP and install it in the mobile or search tesilayun download and install in the mobile 2 Open tesilayun APP from the mobile users have to register for the first time of using it after register input Account Number and Password to enter APP Fig 18 Add Genset Inter...

Страница 16: ...Communication Module 2020 03 10 Version 1 0 Page 16 of 19 3 Open tesilayun APP from the mobile choose Add Genset interface scan the QR code on the Modem and add Modem ID or manually input Modem ID as Fig 12 s Module ID choose Modem type click Confirm and it is OK as Fig 18 Fig 19 Genset Control Interface ...

Страница 17: ...n the list click and enter interface as Fig 19 Fig 20 Controller Interface 5 Click the Icon in Fig 19 enter Edit Genset Profile mainly configure controller information as Fig 20 such as controller brand controller series controller model model ID Communication Port Baud Rate etc Click Save after setting Users can obtain controller genset information by clicking the function icons in Fig 19 ...

Страница 18: ...mal Check connections Check RS232 port is enabled or not on cloud server platform communication port Check settings of genset ID and baud rate are correct or not LINK Communication Abnormal Check connections Check LINK port is enabled or not on cloud server platform communication port Check settings of genset ID and baud rate are correct or not CAN Communication Abnormal Check connections Check CA...

Страница 19: ...MA B1 B8 EVDO CDMA BC0 GSM 900 1800MHz CMM366B 4G S01 CMM366CAN 4G S01 North America FDD LTE B2 B4 B12 WCDMA B2 B5 CMM366B 4G S04 CMM366CAN 4G S04 FDD LTE B2 B4 B5 B13 CMM366B 4G S02 CMM366CAN 4G S02 Europe Africa Korea Thailand Middle East FDD LTE B1 B3 B5 B7 B8 B20 TDD LTE B38 B40 B41 WCDMA B1 B5 B8 GSM 900 1800MHz CMM366B 4G S03 CMM366CAN 4G S03 South America Australia New Zealand FDD LTE B1 B2...

Отзывы: