background image

(949)429

-

3303 

Smartenit.com

 

Technical Support

 

© 2018 Compacta International, Ltd.—Rev 10/3/2018

 

ZBMLCSR and Smartenit are trademarks of Compacta International, Ltd

 

Zigbee is a registered trademark of the zigbee alliance

 

Quick Start Guide

 

Wireless Metering Switch (Load Controller)

 

ZBMLCSR Model #4040C

 

About this Product

 

This high power switch is ideal to wirelessly moni-

tor and control higher voltage (up to 240VAC) 

and/or high current (up to 40A) appliances such 

as electric water heaters, pool pumps, booster 

pumps, etc.  The device interfaces wirelessly with-

in IoT/Home Automation networks where it can 

be controlled by automation hubs using the 

Zigbee protocol.

 

For energy monitoring/management, the device 

measures the energy consumed as well as other 

parameters such as power, voltage, current, pow-

er factor, etc.

 

Install with the tips and suggestions below to get 

the benefits of the Internet of Things through 

your automation controller.

 

Installation

 

For outdoor installation, it is imperative that all water tight precautions are taken to ensure the life and safe-
ty of your load controller.

 

 

The device can be installed indoors or outdoors and may 

be mounted to a junction box or panel through the pro-

vided 

3/4” 

connector, or to a surface through the readily 

accessible mounting holes on the back of the unit.  An 

optional mounting kit consisting of four mounting tabs 

and screws is sold separately.  Using this kit does not re-

quire opening the device.

 

When mounting outdoors through flexible conduit, a wa-

ter

-

tight connector (such as 3/4NPT #P472) must be 

used.

 

To maintain its water tight 

specification, the device 

uses a seal on its lid that 

that matches a 

lip

” 

on the 

case bottom.  If opening 

the device to change the connector or to mount it through the internally accessible 

holes,  disconnect the electrical supply and do not disturb the sealing gasket or 

damage the sealing lip when closing it.  Avoid overtightening the lid screws to main-

tain case integrity and water tightness.

 

Optional Mounting Kit

 

Wire Color

 

Connect To

 

Black

 

Electrical service line 1 (120V: Hot, 240V: L1)

 

White

 

Electrical service line 2 (120V: Neutral, 240V: L2)

 

Red

 

Electrical load

 

LOAD LED

—Green if the 

load is energized (switch 

is ON)

 

SET Pushbutton

Toggles switch on/off, 

restores factory settings, 

joins device to network, 

binds to other devices.

 

STATUS LED

—Indicates 

network and binding status

 

Typical 220V Installation

 

Отзывы: