background image

2016 Compacta International, Ltd. - Rev. 

9/2016

IOT-ZBCID

 

and Smartenit are trademarks of Compacta International, Ltd.

ZigBee is a registered trademark of the ZigBee Alliance

(949) 429-3303

Technical Support

           Smartenit.com

HA Profile (0x0104)                                                                                    Device ID: 

0x0007

                                                                                                                     Combined Interface Device

End 

Point

Cluster 

ID

Cluster Name

Client/

Server

Cluster Description

01

0x0000

Basic

Client/

Server

Attributes for determining basic information about a device, setting user device 
information such as location, and enabling a device

01

0x0001

Power Config

Client/

Server

Attributes for determining more detailed information about a device’s power 

source(s), and for configuring under/over voltage alarms

01

0x0002

Temp Config

Client/

Server

Attributes for determining information about a device’s internal temperature, 

and for configuring under/over temperature alarms

01

0x0003

Identify

Client/

Server

Attributes and commands for putting a device into Identification mode (e.g. 

flashing a light)

01

0x0004

Groups

Client

Attributes and commands for group configuration and manipulation

01

0x0005

Scenes

Client

Attributes and commands for scene configuration and manipulation

01

0x0006

On/Off

Client

Attributes and commands for switching devices between “On” and “Off” states

01

0x0007

On/Off Swith Config

Client

Attributes and commands for configuring On/Off switching devices

01

0x0008

Level Control

Client

Attributes and commands for controlling devices that can be set to a level 

between fully “On” and fully “Off” 

01

0x0009

Alarms

Client

Attributes and commands for sending notifications and configuring alarm 

functionality

01

0x000A

Time

Client

Attributes and commands that provide a basic interface to a real-time clock

01

0x000B

RSSI Location

Client

Attributes and commands that provide a means for exchanging location 
information and channel parameters among devices

01

0x000C

Analog Input (Basic)

Client

An interface for reading the value of an analog measurement and accessing 
various characteristics of that measurement

01

0x000D

Analog Output (Basic)

Client

An interface for setting the value of an analog output (typically to the 
environment) and accessing various characteristics of that value

01

0x000E

Analog Value (Basic)

Client

An interface for setting an analog value, typically used as a control system 
parameter, and accessing various characteristics of that value

01

0x000F

Binary Input (Basic)

Client

An interface for reading the value of a binary measurement and accessing 
various characteristics of that value

01

0x0010

Binary Output (Basic)

Client

An interface for setting the value of a binary output (typically to the 
environment) and accessing various characteristics of that value

01

0x0011

Binary Value (Basic)

Client

An interface for setting a binary value, typically used as a control system 
parameter, and accessing various characteristics of that value

01

0x0012

Multistate Input (Basic)

Client

An interface for reading the value of a multistate measurement and accessing 
various characteristics of that measurement

01

0x0013

Multistate Outpt (Basic)

Client

An interface for setting the value of a multistate output (typically to the 
environment) and accessing various characteristics of that value

01

0x0014

Multistate Value (Basic)

Client

An interface for setting a multistate value, typically used as a control system 
parameter, and accessing various characteristics of that value

01

0x0100

Shade Config

Client

Attributes and commands for configuring a shade

01

0x0101

Door Lock

Client

An interface for configuring and controlling door locks

01

0x0200

Pump Config & Cntrl

Client

An interface for configuring and controlling pumps

01

0x0201

Thermostat

Client

An interface for configuring and controlling the functionality of a thermostat

01

0x0202

Fan Control

Client

An interface for controlling a fan in a heading/cooling system

ZigBee Clusters

Содержание 2011D

Страница 1: ...ands via serial communication This interface is intended for use with applications that can handle serial communication Docklight Scripting is one application that can be used to set up a ZigBee network and control individual ZigBee devices with the IOT ZBCID An understanding of the ZBCID API will be required to modify Docklight scripts For a brief tutorial on how to use Docklight with the pre loa...

Страница 2: ...l parameters among devices 01 0x000C Analog Input Basic Client An interface for reading the value of an analog measurement and accessing various characteristics of that measurement 01 0x000D Analog Output Basic Client An interface for setting the value of an analog output typically to the environment and accessing various characteristics of that value 01 0x000E Analog Value Basic Client An interfa...

Страница 3: ...low or on target 01 0x0402 Temperature Measurement Client Attributes and commands for sensing illuminance level 01 0x0403 Pressure Measurement Client Attributes and commands for configuring the measurement of pressure and reporting pressure measurements 01 0x0404 Flow Measurement Client Attributes and commands for configuring the measurement of flow and reporting flow rates 01 0x0405 Rel Hum Measu...

Страница 4: ...he user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Notice This device complies w...

Страница 5: ... appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement This EUT is compliance with SAR for general population uncontrolled exposure limits in IC RSS 102 and had been tested in accordance with the measurement methods and procedures specified in IEEE 152...

Отзывы: