Giganetix Series
SMARTEK Vision
·
Bana Josipa Jelacica 22c · HR-40000 Cakovec · Croatia
Tel.: ++49 (89) 381 5330 55 · Fax: ++385 (40) 493 819 · [email protected] ·
www.SMARTEKvision.com
In case of the sign
Unable to connect to device
is shown in front of your camera name, there are two
possibilities:
1.
Changing the NIC’s IP-address and subnet mask
2.
Changing the cameras IP-address and subnet mask
For a quick start we recommend the configuration as shown in the table:
NIC (Cameras)
NIC (others)
Camera 1
Camera 2
Camera 3
IP
169.254.0.1
not 169.254.x.x if
255.255.0.0
169.254.1.1
169.254.1.2
169.254.1.x
Subnetmask
255.255.0.0
255.255.0.0
255.255.0.0
255.255.0.0
In all cases it must be ensured that further NIC’s within the PC are not configured for an IP-address within
the same logical network as the NIC for the camera connection.
Step 3:
In the
Devices
list, choose the camera you want to connect to and press the button
Connect
Device
Note:
If connection to the cameras fails, although the camera is listed as available and well configured,
there are most likely two network cards within the PC configured to the same logical network.
Step 4:
As soon as the connection is established successfully, you can start the video stream by pressing
the - button. All camera preferences and features can be accessed via the GenICam™ node-map
under the panel
Device properties
tab
Parameters
. Please note that for changing some features it is
required to stop the video stream first.
Note:
In order to achieve optimal performance and prevent packet loss due to network overload, the use of
Jumbo-packets is highly recommended. If the NIC supports this feature, it can be activated and adjusted in
the properties of the NIC’s driver, usually in its “Advanced Settings”.
5.
Firmware Update
Due to continuous improvements of the cameras and their features it is highly recommended to use the
latest camera Firmware. Please ask your local distributor about the latest firmware release and flash the
firmware via the Smartek Vision GigEVision Client under
Control
Firmware Update
, after connecting to
the target camera.
6.
Power and I/O Interface
EIAJ (Hirose compatible) 12 pin
1
– Power GND
7
– Input 1 +
2
– 10-24V DC input
8
– Input 1 -
3
– Output 1 -
9
– Output 2 -
4
– Output 1 +
10
– Output 2 +
5
– Input 2 -
11
– Input 1 +
6
– Input 2 +
12
– Input 1 -
7.
Further Documentation and Contact
Further technical information on getting started and using the SMARTEK Vision Giganetix Cameras can
be found in the appropriate
Quickstart Guide
and
User's Manual
which can be downloaded from
http://www.smartekvision.com/downloads.php
In case of any further questions please do not hesitate to contact your local sales representative or our
support team via
©
S
M
A
RT
E
K
d
.o
.o
.
2
0
1
3
,
in
fo
rm
a
ti
o
n
is s
u
b
je
ct
to
ch
a
n
g
e
w
ith
o
u
t
p
rio
r n
o
tice
,
V
e
rs
io
n
1
.0
.4
fr
o
m
2
0
1
3
-0
3
-21