background image

Longo programmable controller LPC-2.CH1M

STANDARDS   AND   PROVISIONS:   Standards,   recommendations,
regulations  and provisions  of  the  country  in  which  the  devices  will
operate, must be considered while planning and setting up electrical
devices. Work on  100 .. 240 V AC  network is allowed for authorized
personnel only.

DANGER   WARNINGS:   Devices   or   modules   must   be   protected   from
moisture, dirt and damage during transport, storing and operation.

WARRANTY   CONDITIONS:   For   all   modules   LONGO   LPC-2   –   if   no
modifications   are   performed   upon   and   are   correctly   connected   by
authorized   personnel   –   in   consideration   of   maximum   allowed
connecting power, warranty of 24 months is valid from the date of
sale to the end buyer, but not more than 36 months after delivery
from Smarteh. In case of claims within warranty time, which are based
on material malfunctions the producer offers free replacement. The
method of return of malfunctioned module, together with description,
can be arranged with our authorized representative. Warranty does
not   include   damage   due   to   transport   or   because   of   unconsidered
corresponding   regulations   of   the   country,   where   the   module   is
installed.
This device must be connected properly by the provided connection
scheme in this manual. Misconnections may result in device damage,
fire or personal injury.
Hazardous  voltage  in  the  device  can  cause  electric  shock  and  may
result in personal injury or death.
NEVER SERVICE THIS PRODUCT YOURSELF!
This device must not be installed in the systems critical for life (e.g.
medical devices, aircrafts, etc.).

If the device is used in a manner not specified by the manufacturer,
the degree of protection provided by the equipment may be impaired.

Waste electrical and electronic equipment (WEEE) must be collected
separately!

LONGO LPC-2 complies to the following standards:

EMC: EN 61000-6-3:2007 + A1:2011, EN 61000-6-1:2007, EN 61000-
3-2:2006 + A1:2009 + A2: 2009, EN 61000-3-3:2013

LVD: IEC 61010-1:2010 (3

rd

 Ed.), IEC 61010-2-201:2013 (1

st

 Ed.)

Smarteh   d.o.o.   operates   a   policy   of   continuous   development.
Therefore we reserve the right to make changes and improvements to
any of the products described in this manual without any prior notice.

MANUFACTURER:
SMARTEH d.o.o.
Poljubinj 114
5220 Tolmin
Slovenia

ii

Содержание LPC-2.CH1M

Страница 1: ...USER MANUAL Longo programmable controller LPC 2 CH1M Card Holder module Version 3 SMARTEH d o o Poljubinj 114 5220 Tolmin Slovenia Tel 386 0 5 388 44 00 e mail info smarteh si www smarteh si ...

Страница 2: ...Longo programmable controller LPC 2 CH1M Written by SMARTEH d o o Copyright 2017 SMARTEH d o o User Manual Document Version 3 May 2017 i ...

Страница 3: ...not include damage due to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection scheme in this manual Misconnections may result in device damage fire or personal injury Hazardous voltage in the device can cause electric shock and may result in personal injury or death NEVER SERVI...

Страница 4: ... controller LPC 2 CH1M 1 DESCRIPTION 1 2 FEATURES 2 3 OPERATION 3 3 1 Parameters 3 4 INSTALLATION 4 4 1 Connection scheme 4 4 2 Mounting frame selection 6 4 3 Mounting instructions 7 4 4 Module labeling 8 5 TECHNICAL SPECIFICATIONS 9 6 CHANGES 10 7 NOTES 11 iii ...

Страница 5: ... g room light and air conditioning switched on CH1M module features two PB with which customer is able to activate notification to the personnel One PB activates DO NOT DISTURB message and the other PB activates ROOM SERVICE request LPC 2 CH1M module can be modified on customer request custom front label push buttons changed LEDs added housing color Please contact manufacturer for more information...

Страница 6: ...eatures RFID reader RFID card slot Adjustable LED intensity LEDs for showing activated messages requests do not disturb room service 2 push buttons for activating messages requests do not disturb room service OK LED FAULT X LED Power LED Internal fault LED Internal built in buzzer 2 ...

Страница 7: ...mand Parameter as status means that CH1M module is sending information to main module On the other hand command represents request from main module to module iComm Normal state is 0 If set there is communication error or no communication established iIDNew When new RFID tag is recognized while inserted into CH1M slot this status is set active till RFID card is not removed from the CH1M slot iDNDis...

Страница 8: ...Longo programmable controller LPC 2 CH1M 4 INSTALLATION 4 1 Connection scheme Figure 2 Connection scheme 4 ...

Страница 9: ...3 red FAULT X On RFID key standard NOK or ID card number wrong Off No tag in proximity LED4 green OK On RFID key standard OK and ID card number valid Off No tag in proximity LED5 red Communication On RS 485 communication fault Off RS 485 communication OK LED6 green Power supply On power supply OK Off power supply missing or power off PB1 do not disturb each press toggles request on off PB2 room se...

Страница 10: ...lana Idea Tem Modul Soft Modul Line Master Frames of other vendors most probably suits as well but they were not verified by Smarteh Before installation verify compatibility of non listed frames Module housing has a fin on each side which can be easily removed with knife cutter or pliers This adaptation enables housing to be build in various frame formats with two different depths With regard to f...

Страница 11: ...te shielding material and provisions could be used to avoid interference between panels RFID panel should not be positioned close to conductive areas e g metal frames and metal cover plate Mounting instructions 1 Set the correct RS 485 address S1 switch for LPC 2 CH1M refer to the Table 4 2 Connect interconnection cable to the connector K1 Max allowed tractive force is 30 N 3 Put the LPC 2 CH1M in...

Страница 12: ...tes flush frame mounting module 01 derivation code 001 version code reserved for future HW and or SW firmware upgrades D C 10 10 is the date code 01 week and 10 year of production S N CH1 S9 1000000003 is the serial number CH1 short product name S9 user code test procedure e g Smarteh person xxx 10 year last two cyphers 00000003 current stack number previous module would have the stack number 0000...

Страница 13: ... inserted into LPC 2 CH1M2 Dimensions W x H x D 75 x 49 x 29 mm Weight 40 g Ambient temperature 0 to 50 C Ambient humidity max 95 no condensation Maximum altitude 2000 m Mounting position horizontal Transport and storage temperature 20 to 60 C Protection class IP 20 2 To achieve most reliable RFID card reading results use Smarteh RFID Mifare cards RFID Mifare card must be inserted at least 40 mm d...

Страница 14: ...PC 2 CH1M 6 CHANGES The following table describes all the changes to the document Date V Description 30 05 17 3 Technical data update 23 12 15 2 Pictures update 01 06 14 1 The initial version issued as LPC 2 CH1M module UserManual 10 ...

Страница 15: ...Longo programmable controller LPC 2 CH1M 7 NOTES 11 ...

Отзывы: