Longo programmable controller LPC-2.CA2M

Table 2: K1

K1.1

GND

Ground

K1.2

10  .. 24 V DC

Power supply input

K1.3

RS-485 A

Data receive/send line A

K1.4

RS-485 B

Data receive/send line B

Table 3: LEDs & Buttons

LED1: blue

do not disturb

On: request active
Off: no request

LED2: blue

room service

On: request active
Off: no request

LED3: red

FAULT “ X ”

On: RFID key standard NOK or ID card number wrong
Off: No tag in proximity

LED4: green

OK “ 

√ 

On: RFID key standard OK and ID card number valid
Off: No tag in proximity

LED5: blue

SOS

On: request active
Off: no request

LED6: blue

occupied

On: request active
Off: no request

LED7: red 

Communication

On: RS-485 communication fault
Off: RS-485 communication OK

LED8: green

Power supply

On: power supply OK
Off: power supply missing or power off

Table 4: S1

RS485 ADDRESS

Switch 1

Switch 2

0

OFF

OFF

1

OFF

ON

2

ON

OFF

3

ON

ON

5

Содержание LPC-2.CA2M

Страница 1: ...USER MANUAL Longo programmable controller LPC 2 CA2M Card Reader module Version 1 SMARTEH d o o Poljubinj 114 5220 Tolmin Slovenia Tel 386 0 5 388 44 00 e mail info smarteh si www smarteh si...

Страница 2: ...Longo programmable controller LPC 2 CA2M Written by SMARTEH d o o Copyright 2019 SMARTEH d o o User Manual Document Version 1 June 2019 i...

Страница 3: ...ot include damage due to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection s...

Страница 4: ...controller LPC 2 CA2M 1 DESCRIPTION 1 2 FEATURES 2 3 OPERATION 3 3 1 Parameters 3 4 INSTALLATION 4 4 1 Connection scheme 4 4 2 Mounting frame selection 6 4 3 Mounting instructions 7 4 4 Module labelin...

Страница 5: ...ly read out In case key card for correspondent room is valid the green LED blinks again and a short beep is generated Other devices can be activated at this event like door lock opening turning light...

Страница 6: ...and white glass version Table 1 Features RFID reader LEDs for showing activated messages requests occupied do not disturb room service SOS OK LED FAULT LED Power LED Internal fault LED Internal built...

Страница 7: ...is considered to be active enabled or set If parameter has logical value 0 is considered to be inactive disabled or cleared Parameter can be status or command Parameter as status means that CA2M modu...

Страница 8: ...Longo programmable controller LPC 2 CA2M 4 INSTALLATION 4 1 Connection scheme Figure 2 Connection scheme 4...

Страница 9: ...ED3 red FAULT X On RFID key standard NOK or ID card number wrong Off No tag in proximity LED4 green OK On RFID key standard OK and ID card number valid Off No tag in proximity LED5 blue SOS On request...

Страница 10: ...g metal frames and metal cover plate Mounting instructions 1 Set the correct RS 485 address S1 switch for LPC 2 CA2M refer to the Table 4 2 Drill a hole for cable inlet on desired side and position of...

Страница 11: ...uct name CCDDD sequence code CC year of code opening DDD derivation code EEE version code reserved for future HW and or SW firmware upgrades 3 S N SSS RR YYXXXXXXXXX serial number SSS short product na...

Страница 12: ...odule Interconnection connector type RJ 12 6 6 Power consumption 1 W RFID type ISO IEC 14443 A MIFARE Max reading distance 4 cm Dimensions W x H x D 120 x 80 x 60 mm Weight 200 g Ambient temperature 0...

Страница 13: ...ngo programmable controller LPC 2 CA2M 6 CHANGES The following table describes all the changes to the document Date V Description 14 07 19 1 The initial version issued as LPC 2 CA2M module UserManual...

Страница 14: ...Longo programmable controller LPC 2 CA2M 7 NOTES 10...

Отзывы: