These are described in the following sections. 

COMMAND_CLASS_BASIC 

This command class can be used to switch the boiler on/off (or to know the current status). 

However, the auto-report of this CC was not implemented for performance reason. 

Therefore, to perform the same operation is recommended to use the 

COMMAND_CLASS_SWITCH_BINARY. 

COMMAND_CLASS_SWITCH_BINARY 

This command class can be used to switch the boiler on/off (or to know the current status). 

Moreover if, for external reason, the boiler switch itself on/off an auto-report to node 1 of 

the network is triggered. 

COMMAND_CLASS_THERMOSTAT_SETPOINT 

This command class can be used to manage the setpoints of the boiler. Is important to 

known that the max and min value of these setpoints are not reported by this command 

class (the reported values are just a 'small' minimum and a 'big' maximum). These values 

are instead reported with the CONFIGURATION command class. This was done to 

support the write operation of these 2 values in some future developments. The map 

between the 'mode' and the setpoint is as below, while the unit of each measure is 

communicated correctly in the report message of the command class. 

 

Modalità (hex) 

Modalità (dec) 

Misura 

0x01 

Heating Setpoint 

0x0D 

13 

DHW Setpoint 

COMMAND_CLASS_SENSOR_MULTILEVEL 

This command class maps a series of measures that are obtained from the boiler. The 
map between the 'Sensor type' and the provided measure is as below, while the unit of 
each measure is communicated correctly in the report message of the command class. 

Содержание MyOT 01335-2080-00

Страница 1: ...or for OpenTherm boilers the latest generation device that allows you to monitor the performance of the OpenTherm boilers on which it is installed Z Wave certified it is compatible with any gateway th...

Страница 2: ...near sharp or abrasive objects prevent people from walking on them 8 Keep out of reach of children 9 Do not carry out any maintenance on the device but always contact the assistance network 10 Contac...

Страница 3: ...e waste collection service or the center where you purchased the product Disclaimer SmartDHOME Srl cannot guarantee that the information regarding the technical characteristics of the devices in this...

Страница 4: ...dictive Maintenance process the implementation of automatic customer support processes Features Z Wave protocol Series 500 Radio signal power 1mW Radio frequency 868 4 MHz EU 908 4 MHz US 921 4 MHz AN...

Страница 5: ...to IoB cloud A few tips that can aid you 1 Boiler and Thermostat OpenTherm connections have no polarization 2 Pay close attention to the 5V power connection respecting the and 3 Pay close attention t...

Страница 6: ...s No connection to the local network No connection to the SmartDHOME server no Internet connection server temporarily unavailable etc Wi Fi Configuration WARNING The device has several communication m...

Страница 7: ...o end the process press the CLOSE button on the top right The LEDs on the MyOT device will stop flashing alternately At the end of the Device Configuration the IoB will be operational with the new con...

Страница 8: ...dwifi the Key of the Wi Fi chosen A white screen with the inscription OK will be displayed 7 Open the browser and enter the following third link http 192 168 4 1 exit A white screen with the inscripti...

Страница 9: ...ed to manage the setpoints of the boiler Is important to known that the max and min value of these setpoints are not reported by this command class the reported values are just a small minimum and a b...

Страница 10: ...1 Boiler heating modulation 0x3E 62 Boiler water temperature 0x3F 63 DHW Temperature COMMAND_CLASS_CONFIGURATION This command class maps a series of parameters that are obtained from the boiler The ma...

Страница 11: ...nd customer support Visit our website at the link http www ecodhome com acquista garanzia eriparazioni html If you encounter technical problems or malfunctions visit the site http helpdesk smartdhome...

Отзывы: