11
INSTALLATION AND OPERATION
6 position connector - TB5
Xenon 1
Xenon 2
Xenon 3
Masking Scope
Masking Common
Masking Flat
6 position connector - TB4
Curtains Close
Curtains Common
Curtains Open
Douser Close
Douser Common
Douser Open
6 position connector - TB2
Motor
Motor
N/C
N/C
Slide Projector
Slide Projector
Controller Wiring Information
This page shows the functions for the 6 position pluggable terminal strips. All relays are rated at 10
Amps. If you are controlling a higher current device, then use an external relay of the proper
capacity controlled by the on board relay. Use wire size appropriate for the load to be controlled.
6 position connector
TB6
N/C
Com
Data Out Hi
Data Out Lo
Data In Hi
Data In Lo
Use the XENON 1 and XENON 2
terminals for the Ignitor control
circuit. Do NOT use XENON 3
except in special cases as
directed by the factory.
R39 NOT installed unless
directed by the factory.