1

INSTALLATION AND OPERATION

Devices, Inc.

5945 Peachtree Corners East

Norcross, Georgia 30071

1-800-45-SMART or 770-449-6698

SHOWMATION

Automation Control System

Version 4.xx

Installation and

Service Manual

Made Right in the U.S.A

Содержание Showmation

Страница 1: ...AND OPERATION Devices Inc 5945 Peachtree Corners East Norcross Georgia 30071 1 800 45 SMART or 770 449 6698 SHOWMATION Automation Control System Version 4 xx Installation and Service Manual Made Righ...

Страница 2: ...occurs during the warranty period the unit will be repaired or replaced at our option without charge for materials or labor If air freight is requested by the dealer the difference between air and sur...

Страница 3: ...OR PANEL and the CONTROLLER are separate pieces which mount at any convenient place in your console A wall mount package is also available which houses the OPERATOR PANEL and the CONTROLLER if console...

Страница 4: ...enon lamp ignitor and many lamphouses especially older ones have extremely electrically dirty ignitors Please see the diagram below for suggested ways to clean up the lamphouse Having an EMI suppresse...

Страница 5: ...erlocks may run simultaneously Each SHOWMATION has setup switches to properly identify itself to the WATCHDOG annunciator panels The OPERATOR PANEL has a scratchproof Lexan overlay which matches the S...

Страница 6: ...s and through several wiring harnesses for the manual bypass functions The harnesses are terminated to Faston connectors on the Operator Panel end for ease of connec tion The Controller end of the har...

Страница 7: ...from the pluggable terminal strips to the appropriate points in the console wiring Use wire sizes appropriate for the load you are controlling First we are assuming a console mounting which will prob...

Страница 8: ...ftware version is listed on the label on top of the micro controller IC labeled U8 on the Controller printed circuit board Annunciator ID Diagram on Page 11 There is another DIP switch package labeled...

Страница 9: ...ector on the Operator Panel circuit board Plug the other end of the cable into the connector on the Controller There are six wiring harnesses supplied which are used to connect the Operator Panel manu...

Страница 10: ...e turned upside down The PC board will only mount one way on the panel There are four mounting holes on the metal back plate which will pass 8 machine screws These are accessible without removing the...

Страница 11: ...ows the functions for the 6 position pluggable terminal strips All relays are rated at 10 Amps If you are controlling a higher current device then use an external relay of the proper capacity controll...

Страница 12: ...then use an external relay of the proper capacity controlled by the on board relay The Interlock functions on TB3 will be wired in the field Use one 2 conductor shielded cable for each of the two inte...

Страница 13: ...Operator Panel Terminal Designator and Cable Color Controller Main Board Terminal Designator and Cable Color Bypass Function F1 BLUE 24 W FASTON TB1 4 BLUE 24 STRIPPED Lights Common F2 RED 24 W FASTON...

Страница 14: ...any cue The START cue will open the douser and advance the SHOW GRAMMER II to the START position Format lens and masking and lighting changes which have been programmed on the SHOWGRAM MER II START po...

Страница 15: ...ATION is not functioning correctly These are self explanatory Normally you should not have to use the manual switches unless there is a problem such as the lens and masking are not in the correct form...

Страница 16: ...MOTOR and DOUSER toggle switches are for manual operation and will not normally be used These toggle switches control the show support functions The MASKING and LENS switches are for manual operation...