User Manual
SMART ICE S30B Laser Therapy System
Before operating this unit, please read this manual completely.
Страница 1: ...User Manual SMART ICE S30B Laser Therapy System Before operating this unit please read this manual completely ...
Страница 2: ... 5 3 1 Turn on The System 5 3 2 Login System 6 3 3 Treatments Data Setting 6 3 4 Starting The Treatment 7 3 5 After The Treatment 7 3 6 Other Functions 8 3 6 1 Quick Start 8 3 6 2 Pateints Data 8 3 6 3 Pre set Protocol 9 3 6 4 Video Tutorial 10 3 6 5 Account Management 10 3 6 6 System Setting 12 4 Maintenance and Fault Diagnosis 13 5 Product list 13 ...
Страница 3: ...ystem without our permission Only our company after sales staff or authorized professional staff could adjust or fix the system 4 Please turn off the key switch turn off the rocker switch unplug the power cord if long time not use the system Keep the system in a dry and cool environment 5 Clean the system with alcohol if there is dust or greasy dirt on the system case 1 1 System Security Device SM...
Страница 4: ... on the front panel of the host Safety interlock The safety interlock is used to open and close the laser light output control system of the device Only when use the safety interlock provided by our company can ensure the normal use of the equipment which can prevent the illegal use of this machine Remove the safety interlock from the special transparent accessory bag and insert the safety interlo...
Страница 5: ... illuminate the human diseased tissue through the semiconductor laser beam to reduce or eliminate pain and improve Local blood circulation tissue repair rapid anti inflammatory and other effects This laser is in the near infrared band which can penetrate deep into the tissue and act on the body so that the tissue can absorb light energy well and relieve pain Outline of the Machine The SMART ICE ph...
Страница 6: ...e Φ10mm Working mode CW Single Pulse Repeat mode B mode Power Supply AC100 125V 60Hz Input Power 300W Dimension 425mm 465mm 310mm Weight 12kg Item No Name Item No Name 1 Display 6 Press button 2 Key switch 7 Power cord socket 3 Emergency switch 8 Safety interlock 4 Treatment handle 9 USB socket 5 Treatment handle hanger Treatment handle button ...
Страница 7: ...e INTERLOCK port on the rear panel of the main unit as shown in the figure below Figure 3 1 Key switch Figure 3 2 Safety interlock Step 3 Insert the power plug into the AC110V wall power then press the press switch on the rear panel of the host to I to turn on the device turn the key switch to ON click Unlock on the front panel of the host to ensure that the emergency stop switch is turned off The...
Страница 8: ...atments Data Setting Click Logo SMART ICE on the upper left corner to enter the main interface you can choose the appropriate treatment plan for the patient In this interface you can make a treatment plan there are four working modes including CW mode Pulse mode Repeat mode B mode you can set the power pulse width Timer etc before thetreatment ...
Страница 9: ...rface after setting the parameters click Ready to enter the Ready state press the button of the treatment handle and the treatment head emits light to start treatment Note After setting the treatment time the interface will count down to display the remaining treatment time 3 5 After The Treatment When the treatment is completed the interface will display a note to confirm whether to save the trea...
Страница 10: ...r the treatment interface 3 6 2 Patients Data Click Patients on the left side of the screen In this interface you can query the patient by entering the phone number and click the corresponding number icon to display detailed treatment information On the patient treatment information display interface you can view the treatment records of each stage of the patient such as treatment mode time power ...
Страница 11: ...r first treatment time etc and click the Save icon to save 3 6 3 Pre set Protocol Click Pre set Protocol on the left side of the screen and then click the Treatment Area icon in the interface Develop a treatment plan according to different treatment sites body type skin color pain level and pathogenesis ...
Страница 12: ...l Click Video Tutorial on the left side of the screen and click the video name you can watch the tutorial video 3 6 5 Account Management Click settings on the left side of the screen and then click Account to view system users The system has a default manager account The manager can create or delete a doctor account but ...
Страница 13: ...User Manual 11 the doctor cannot perform this operation Note Add new account delete account edit account information name avatar Click the account avatar icon to change the account password ...
Страница 14: ...eft side of the screen and then click System The interface will display the device model the SN number of the host and the treatment head and the system software version number On this interface you can adjust the sound volume set the current display time of the system and update the system by inserting a USB flash drive and clicking USB Update ...
Страница 15: ...ice Department The screen shows E STOP Emergency stop button is lock Click unlock button on the front panel The screen shows E KEY The key switch is off Turn on the key switch The screen shows E SKIN The skin temperature is too high Suspend the light to be used after the temperature drops The screen shows E LD The laser temperature is too high Suspend the light to be used after the temperature dro...