> the housing cover has been removed or can no longer be closed or locked,

 

> sufficient protection against splashing water and/or foreign objects is obviously no longer evident,

 

> there is functional or visible damage to the charging cable

 

> or the wallbox does not function properly or has been otherwise damaged.

DANGER! 

 

Should you detect damage to the housing, charging socket or charging cable, you must 
immediately discontinue installation or take the already installed wallbox out of opera-
tion via the upstream miniature circuit breaker(s) (in the following called MCB(s), see also 
“Glossary & Definitions.” on page 27) in your domestic power supply and the RCCB: No 
further use of the wallbox is permitted in this case! Please contact your local smart tech-
nical support!

Notes regarding installation.

Please observe the following instructions for the installation of your smart Wallbox:

 

> The device must always be connected to the protective earth conductor of your electricity supply. 

The protective earth connection will be made and checked by the installing contractor. After instal-
lation, only qualified specialist electrical contractors may make changes.

 

> At all times comply with local safety regulations for the country in which you operate the wallbox.

 

> For proper operation, the power supply for the wallbox must be protected in the domestic power sup-

ply with suitable MCB(s) and RCCB.

 

> To disconnect the wallbox completely from the electricity grid, the power supply must be inter-

rupted using the upstream MCB(s) and RCCB.

 

> Ensure that the rated voltage and rated current of the device comply with the parameters of your lo-

cal electricity grid and that the rated output is not exceeded during the charging procedure. 

 

> The wallbox should not be installed in areas of high pedestrian traffic. Installation along thorough-

fares and marked escape routes should be especially avoided. 

 

> Never install the wallbox in a confined space. In particular, you must ensure that the vehicle can 

be parked at a suitable distance from the wallbox for charging and connected without any strain on 
the charging cable. The distance between vehicle and wallbox should be at least 50 cm and no more 
than 5 m. You may deviate from this recommendation depending on the model variant of the wallbox 
(length of charging cable) and local conditions.

 

> You must not under any circumstances make any changes to the housing or the internal wiring of 

the wallbox: Any disregard of this instruction represents a safety risk, fundamentally breaches the 
guarantee provisions and may void the warranty with immediate effect.

Содержание 3W72S2

Страница 1: ...smart Wallbox Installation manual for specialist electrical contractors...

Страница 2: ...r local smart technical support This manual in its entirety or in parts must not be reproduced stored electronically or otherwise transmitted electronically electrically mechanically optically chemica...

Страница 3: ...on site 7 Requirements for the power supply 8 Mechanical installation of the mounting plate 12 Taking the wallbox into operation 03 14 Error detection and solutions 14 Operational disruptions and solu...

Страница 4: ......

Страница 5: ...s manual is included with the smart Wallbox and documents the steps and settings required for in stalling the wallbox taking it into operation as well as for resolving malfunctions during operation Fo...

Страница 6: ...NING After opening the housing dangerous voltages may be present on the inside of the wallbox as well as on components you are able to touch General safety information Please pay attention to the foll...

Страница 7: ...o be used by persons with limited physical sensory or mental abilities including children and or lacking knowledge unless they are supervised by someone responsible for their safety or have received i...

Страница 8: ...egulations for the country in which you operate the wallbox For proper operation the power supply for the wallbox must be protected in the domestic power sup ply with suitable MCB s and RCCB To discon...

Страница 9: ...any time Should a malfunction occur you can identify the cause by its specific LED error code without having to open the housing After be ing taken into operation by a specialist contractor the smart...

Страница 10: ...roduct sticker Fixed charging cable according to IEC 62196 2 Type 1 ca 7 4 m charging output 7 2 kW WARNING The information and technical specifications contained in this manual relate exclusive ly to...

Страница 11: ...protection from weath er related pollution Requirements for the power supply The following standards must always be considered for the electrical installation of the smart Wallbox All regulatory requi...

Страница 12: ...owing link www yourwallbox de Mains_Connection_Schemes Mechanical installation of the mounting plate After determining the mounting site for the wallbox you can begin with mechanical installation For...

Страница 13: ...red please remove one of the plastic tongues in tended for the power supply cable with a suit able pair of pliers a cutter or drill 83 3 Place the mounting plate on the chosen mount ing surface Use a...

Страница 14: ...nal damage If possible only re move the protective film from the housing cover just before completing installation 8 Use the screwdriver to loosen the TX20 screw holding the internal electronic compon...

Страница 15: ...nnected as follows Designation Wire colors Connection coding Current carrying conductor phase 1 Brown L1 Neutral Blue N Protective earth Green Yellow PE DANGER Please note that the electronic componen...

Страница 16: ...ousing cover upwards so that it clicks into the housing and lock it with the triangular key supplied Taking the wallbox into operation After mechanical and electrical installation you must check the c...

Страница 17: ...n the blue LED flashes every 5 seconds the green LED and the red LED go out The vehicle can now be connected for charging The charging procedure itself is described in the operating manual included PL...

Страница 18: ...ermanently contact your lo cal smart technical support The wallbox has not been connected in ac cordance with the re spective type of mains power connection for the country of instal lation Check your...

Страница 19: ...n LED flashes three times then the blue LED flashes once the red LED is continu ously ON Solution In both cases switch the power supply off and then back on again If the error continues to occur take...

Страница 20: ...cable If the cable does not show signs of damage the vehicle must be checked Please contact a qualified specialist repairer 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms Descri...

Страница 21: ...llbox out of operation see Taking the product out of and back into operation on page 21 and contact your local smart technical support 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 20...

Страница 22: ...voltage 4 Ground and short circuit 5 Cover or prevent access to adjacent parts under voltage Otherwise there is a risk of severe injury or even death through electric shock Two rotary encoders S1 and...

Страница 23: ...be indicated by the LED display after you have switched the power supply to the wallbox back on in step 3 Error description LED status The settings could not be saved in the memory The wallbox was set...

Страница 24: ...off automat ically all LEDs are illuminated 6 To terminate testing mode switch off the power supply of the wallbox via the upstream MCB s and RCCB 7 Remove the internal electronic com ponents cover S...

Страница 25: ...t the operation of the wallbox It is therefore recom mended not to make any changes and to generally leave the S3 rotary encoder in the 0 position 2 0x02 3 0x03 4 0x04 5 0x05 6 0x06 7 0x07 8 0x08 9 0x...

Страница 26: ...e error can still not be resolved repairs must be carried out For this purpose you must take the wallbox out of operation uninstall it and return it via smart technical support In addition to the wall...

Страница 27: ...Customization internal RS485 interface no user installer access Operating temperature 30 C to 50 C Storage temperature 30 C to 85 C Relative humidity 5 to 95 no condensation Class of protection I Ove...

Страница 28: ...ions The smart Wallbox is delivered fully assembled and quality checked All dimensions as well as the mounting points are indicated in the scale drawings below Mounting plate Plan and elevation all di...

Страница 29: ...lbox Appendix 25 Wallbox with fixed charging cable Plan and elevation all dimensions in mm 394 143 492 134 194 400 492 134 194 Contact chart Type 1 Type 2 Type 2 Type 1 PE N L3 PP PE L1 L2 CP CS L2 N...

Страница 30: ...ehicles DIN EN 61851 1 2012 01 Conductive charging systems for electric vehicles Part 1 General re quirements E DIN EN 61851 22 2011 04 Conductive charging systems for electric vehicles Part 22 AC cha...

Страница 31: ...rading names or company names marked here as such are or may be trademarks or registered trademarks of their respective owners All rights not explicitly granted here are reserved The absence of explic...

Страница 32: ...nic devices are taken back by the manufacturer in order to have them properly disposed of or recycled Therefore devices marked with this symbol may not be disposed of as part of unsort ed domestic was...

Страница 33: ...esia Tahiti 60 Hz 220 V L1 N x Hong Kong 50 Hz 220 380 V L1 L2 L3 N x India 50 Hz 220 380 V L1 L2 L3 N x 230 400 V 240 415 V Indonesia 50 Hz 127 220 V L1 L2 x 220 380 V L1 L2 L3 N x Israel 50 Hz 230 4...

Страница 34: ...e 50 Hz 230 400 V L1 L2 L3 N x United Arab Emirates 50 Hz 220 380 V L1 L2 L3 N x 240 415 V Vietnam 50 Hz 127 220 V L1 L2 x 220 380 V L1 L2 L3 N x Region Country Local frequency Local voltage domestic...

Страница 35: ...smart Wallbox 31...

Страница 36: ...rt www smart com The manufacturer may have made minor technical modifications to the product after publication of this installation manual This may also have led to minor discrepancies in the appearan...

Отзывы: