KEY FUNCTIONS

        

A    B     C     D      E    F

A = ON/OFF KEY

 - When the

SMT-AZC is not locked, this key allows 
the thermostat to be turned ON or OFF. 
When in the OFF position, the damper 
is also driven closed.

B = STATUS KEY 

- Pressing the 

STATUS key displays the UNIT number, 
ZONE number, DUCT temperature and 
DAMPER position.

and 

D = UP 

and

 DOWN KEYS 

These keys are used to increase or 
decrease the setpoint as well as change 
thermostat setup values.

E = SETUP KEY 

- This key is used to 

toggle through the thermostat setup 
menu.

F = ENTER KEY 

This key is used to 

enter changes as well as exit the setup 
menu.

ATTACHING THERMOSTAT TO 
THE SUBBASE

When attaching the thermostat to the 
subbase, first place the hinged access cover 
on by fitting the plastic molded pins into the 
grooves at the top of the thermostat. 
Carefully align the two standoffs located at 
the top of the thermostat with the slots in the 
top of the subbase. Allow the thermostat to 
swing downward and gently push until the 
connector pins are fully seated into the 
terminal blocks.

SETUP

Apply 24 Volts power to the thermostat. The 
LCD will momentarily display all icons. 
(Figure 1)

FIGURE 1

Содержание SMT-AZC

Страница 1: ...SMT AZC INSTALLATION OPERATION MANUAL www smarttemp com VERSION 2 0 22 o OFF...

Страница 2: ...Smart Temp reserves the right to change the specifications of the SMT AZC without notice All right reserved Smart Temp Australia Pty Ltd Intellectual rights apply DISASSEMBLY Insert a small coin in th...

Страница 3: ...connecting pins to the terminal blocks Use a properly sized screwdriver and land each wire to its dedicated terminal Do not over tighten the terminal screws Check to see that all wires are landed corr...

Страница 4: ...om Heating Cooling Equipment Damper To downstream vents Smart Temp Belimo LM24T Actuator 1 2 3 C R PO PC DS DS Y W A B 24Vac Damper Sensor Cool Heat Modbus SMT AZC Zone Control Thermostat SW 1 OFF SW...

Страница 5: ...e through the thermostat setup menu F ENTER KEY This key is used to enter changes as well as exit the setup menu ATTACHING THERMOSTAT TO THE SUBBASE When attaching the thermostat to the subbase first...

Страница 6: ...ncrements Figure 3 SETTING THE MAXIMUM DAMPER POSITION Press the SETUP key again and the LCD will display the maximum damper position for heating and cooling The factory default is 100 which means the...

Страница 7: ...actory default is 68 F Press the UP and DOWN keys to change the cooling limit setting It is strongly recommended that the limit not be set below the factory default setting Figure 8 SETTING THE ACTUAT...

Страница 8: ...ress the SETUP key again and the LCD will display the temperature calibration offset The factory default setting is 0 Typically it is not necessary to adjust the temperature calibration offset as the...

Страница 9: ...P key until the word DAMPER appears and then continue pressing the SETUP key to toggle through the functions to where you left off CHECKING THERMOSTAT STATUS POINTS After the thermostat is locked and...

Страница 10: ...ged within the setpoint limits Figure 14 ADVANCED FUNCTIONS DAMPER POSITION OVERRIDE The SMT AZC has a damper position override feature to assist in air balancing and bypass damper setup With the ther...