![Smart Technologies AM70-L Скачать руководство пользователя страница 115](http://html1.mh-extra.com/html/smart-technologies/am70-l/am70-l_setup-and-maintenance-manual_1296210115.webp)
Appendix C
109
smarttech.com/kb/170450
-
Appendix C:
Resetting the room system to
factory defaults
This appendix explains how to reset the room system to factory defaults.
In most situations, you should reset the room system from the
Settings
screen. However, if the
room system is in an unrecoverable state or the
Settings
screen is otherwise not accessible, you
can reset the room system from the BIOS.
To reset the room system from the Settings screen
1. On the console, press Options, and then press Settings.
The
Enter your credentials
screen appears.
2. Type the room system administrator account’s user name and password in the text boxes, and
then press Authenticate.
The room system restarts.
3. Type the room system administrator account’s password, and then press ENTER.
The Lync Admin Console appears.
4. Press Web Updates.
5. Press Reset the Device to Factory Image.
The room system restarts, and the software is reset to factory defaults.
6. Complete the procedure in
Configuring your room system’s software
To reset the room system from the BIOS
1. Turn off your room system (see
2. Connect a USB keyboard to the Lync appliance.