background image

 

 
 
 

Page 

1

 of 

17

 

 

 

 

 

Smart Node

 

Touch Switches

 

Model: TS.2S (NL)

 

Product Guidance 

 

 

 

 

 

 

 

 

Содержание Touch Switches TS.2S NL

Страница 1: ...Page 1 of 17 Smart Node Touch Switches Model TS 2S NL Product Guidance ...

Страница 2: ...sic Load explanation 5 3 1 Power Supply 5 3 2 Front End Touch Board 6 4 Installation Guide 8 4 1 Power Supply Installation 8 4 2 Touch Board with the power supply 10 5 Operations 11 6 Installation Special Case 14 5 1 Invertor Connections 14 5 2 Two Way Connection 14 6 Declaration 16 7 GUARANTEE and WARRANTY period 17 ...

Страница 3: ... other major companies like Legrand Schneider and many others This customization is only done on a prior order to the company Smart Node Touch Switches are capable of regulating multiple loads from a single regulator present This is a very unique feature of the Smart Node Smart Node has 8 different modules in Touch Switches TS 8S1R TS 8S TS 4S1R TS 4S TS 2S NL TS 2S HL TS 1C and TS 1B The advantag...

Страница 4: ...The two loads are of the type regular load The combination of the load possible with TS 2S NL is described in the further sections Total Loads 2 Modular 2M Colour Available Black White Two way possibility 1 Regular load Invertor connection Possible Here in TS 2S NL model 2S indicates a total of 2 Touch Pads a total of 2 loads There is no on board regulator present here ...

Страница 5: ... of TS 2S NL is shown below Here Ph indicates Phase Live wire input N indicates Neutral input and HP indicates Heavy Phase input The loads connected to the different output terminal are described in detail below L Regular load Here the possible connections of loads are light fan 6A plug and many others If a 6A plug is connected to this terminal then the examples of appliances that can be connected...

Страница 6: ...do not recommend to group more than 5 LED lights with this load If a fan is connected to this terminal we can only turn on off the fan We cannot change the fan speed Multiple fans with a maximum rating of 1000 watts can be connected here We recommend connecting a BLDC fan here 3 2 Front End Touch Board The front end Touch Board is shown below Here the number indicates the load correspondence to th...

Страница 7: ...ing Material of the Touch Board Acrylic Power Consumption 0 6W idle and 3W On Full Load Back End Size L x W x H 66mm x 50mm x 32 5mm Weight 200g Load Wise Maximum Connection Capacity L Resistive 1500W Inductive 1000W Capacitive 750W Examples of Resistive loads are a filament based lamp iron hair dryer etc Examples of Inductive loads are blender mixer fan old tube light motor etc Examples of capaci...

Страница 8: ... front end Touch Board We will go deep into each section below The TS 2S NL box contains 1 One front end Touch Board 2 One power supply 3 One touch Switch Connector 4 1 Power Supply Installation Before going through the steps of installing the hardware let us first have a look at the normal wiring behind a switch board where traditional switches are connected to the respective load to turn on or o...

Страница 9: ...h to insert to Touch Switch Disconnect the load wires from the traditional switches and also remove the phase Live wire from the switches Now label the load wires as per the load connected for further easy identification 3 We need to connect the wire of each load which were removed from the switches to each terminal of the power supply module as per the load type The detailed information about the...

Страница 10: ...ys 2 Insert the switch connector provided to the male connector block on the power supply located at the left side of the green terminals with the small arrow indicated on the switch connector facing in the front as shown in the figure below 3 Now we need to connect the other end of the connector with the Smart Node front end Touch Board 4 Now insert the back plate to the wall with the screws prov...

Страница 11: ... also a presence of dim white light to recognize the Touch Switches during the night 2 Remote Smart Node Touch Switches can be operated using our IR remote The remote provided is universal The remote layout is as shown below We can turn on off any load using this remote We can also set the fan speed or change the brightness of any dimmable light using this remote Apart from these basic functions t...

Страница 12: ...he night using the remote Single Universal Remote One Smart Node remote can work for multiple Touch Switches Master Control Using a single button you can turn on and turn off all the loads on a Touch Switch Remote button learning By default all the buttons on the Touch Switch are assigned a number on the remote starting from 1 But in certain condition need arises when we need to change the assigne...

Страница 13: ...Page 13 of 17 ...

Страница 14: ...to connect other loads of TS 2S NL with invertor we need to connect the inverter phase with the Ph terminal as follows Loads Ph Terminal L2 P1 L1 P2 6 2 Two Way Connection In TS 2S NL a total of only one load is possible to make it work as two way The load connected with L1 can only be made two way Two way connection depends whether we have connected traditional switches or Smart Node Touch Switch...

Страница 15: ...Page 15 of 17 If traditional switches are connected on the other side then the two way connection is possible and the wiring diagram will be as follows ...

Страница 16: ...ge of contents in this document in any form is prohibited Smart Node Automation operates a policy of ongoing development Thus Smart Node Automation reserves the right to make changes or improvements to the products described in this document without prior notice If you need further assistance please write to us at support smartnode in or call us at 91 9327958744 You can also refer FAQs on our webs...

Страница 17: ...ecified in the manual and specifications e Damage caused by user including but not limited to breakage of the module wrong installation no electrical earthing f Spillages or moisture including but not limited to exposure or contact with any liquid g Neglect h Accidents including but not limited to improper voltage or power supply i Unauthorised modifications including but not limited to the openin...

Отзывы: