This section includes a list of error messages and frequently asked
questions for issues you may encounter with your blood pressure
monitor.
TROUBLESHOOTING
PROBLEM SYMPTOM
CHECK THIS
REMEDY
No power
or Low
batteries
Error
message
Display
will not light up
Batteries are exhausted.
Replace with new batteries.
Insert the batteries
correctly.
Batteries are inserted
incorrectly.
E 1 shows
E 2 shows
E 3 shows
Movement can affect the
measurement.Relax for a
moment and then
measure again.
E 4 shows
EExx,shows on
the display.
A calibration error
occurred.
Retake the measurement.
If the problem persists,
contact customer service
for further assistance.
Refer to the warranty for
contact information and
return instructions.
E 5 shows
AC adapter is inserted
incorrectly.
Insert the AC adapter
tightly.
or
shows
The monitor detected
motion,talking or the
pluse is too weak
while measuring.
Warning
message
Out shows
Out of measurement
range.
Relax for a moment.
Refasten the cuff and then
measure again. If the
problem persists, contact
your physician.
SPECIFICATIONS
Refasten the cuff and then
measure again.
The measurement
process does not detect
the pulse signal.
Loosen the clothing on the
arm and then measure
again.
Not able to calculate,
measurement failed.
Relax for a moment and
then measure again.
Failed to communicate
with the server.
Contact customer service.
No access to network.
E 6 shows
Contact customer service.
The cuff is not secure
or abnormal inflation.
Digital LCD V.A.78 mm*92 mm
Approx.393g (Excluding the batteries)
Approx.154.3 mm*121.5 mm*68.1 mm
External dimensions
Display mode
Measurement mode
Oscillographic testing mode
Weight
Mode of operation
Continuous operation
Measurement range
Rated cuff pressure:
0 mmHg ~ 299 mmHg (0 kPa ~ 39.9 kPa)
Measurement pressure:
SYS: 60 mmHg ~ 230 mmHg (8.0 kPa ~ 30.7 kPa)
DIA: 40 mmHg ~ 130 mmHg (5.3 kPa ~ 17.3 kPa)
Pulse value: (40-199) beat/minute
Accuracy
Pressure: within ±3 mmHg (0.4 kPa)
Pulse value: ±5%
Power supply
Battery powered mode: 6VDC 4×AA batteries
AC adapter powered mode: 6V 1A (not included)
(Please only use the recommended AC adapter).
4×AA batteries, user manual
Attachment
22 cm~45 cm
Measurement perimeter
of the upper arm
Multiple patient multiple use
Type of use/reuse
Mobility
Hand held medical device to be used on a resting
patient.
Type BF applied part
Degree of protection