③
Aim at target (left
position). Press ENT
④
Aim at target (right
position).Press
ENT
Power on automatically.
⑤
Finish adjustment.
Repeat,if not within
standard.
9.7
Check & Adjustment of the laser confocal and
coaxial
(This step was done after finishing the inspection and
adjustment of Item 9.4 and 9.5)
Laser confocal
Send the laser after aiming at the target,and then check the
facula’s diameter.It should be minimum.If it is not,loose the
screw on the laser pedestal,and move the pedestal until the facula
be smallest.
Laser coaxial
The crossline should be in superposition with the facula after
aiming at the target.Make the facula in the center of the crossline
through the four screws on the pedestal.(as the picture below)