US SL 580 MAXI 03/2016
20
Close slide valve. Disconnect one vacuum circuit at hose coupling, and then open the slide valve for vacuum
suction again. If the vacuum suction on the pressure gauge for disconnected circuit is now constantly 0.6,
there will be a fault on the hose set or at the suction cups in disconnected vacuum circuit. Test the same
procedure in case of fault on the other vacuum circuit system. You may listen for leaks.
Vacuum Guard (two)
Vacuum Guard light green when
pump is running (2 circuits)
Vacuum guard light - red when
vacuum suction has been
attained
(Note: Frame no.)
© 2006 Copyright. www.smartlift.dk
© 2006 Copyright. www.smartlift.dk
Vacuum pump
Check valves – 2 ci filters
© 2006 Materialet er ophavsretligt beskyttet
www.smartlift.dk
© 2006 Materialet er ophavsretligt beskyttet
www.smartlift.dk