Smart Generators Operating Instructions
SG13001
shutdown, always check the engine oil
level before startup.
Operation
ELECTRIC START
NOTE: Read Operator’s Manual carefully
before operating this unit. Always
make sure the unit is level and properly
grounded. Check engine oil before
starting.
1. Fuel selection is performed at the
T-joint. Set up the T-joint for its
intended gas usage (LP or NG). (The
first picture shows the regulator setup
for LP and the second picture shows
the regulator setup for NG.)
2. Connect and tighten the fuel hose
fitting to the proper outlet.
3. Install the cap to plug the T-joint
outlet that is not used.
4.
Attaching the Propane (LP) or
Natural Gas (NG) hose to the
generator.
Attach the propane or
natural gas hose to the male flare
fitting on the front of the low pressure
regulator using a wrench. Do not over
tighten.
Note: The LP and NG hoses use
different sized adapters.
5.
Attaching the Propane (LP) or
Natural Gas (NG) hose to the fuel
source.
The other end of the hose
must be connected to
(1) the LP tank by inserting the
reverse thread POL (located on the
regulator end of the hose) into a
propane tank using a wrench. Make
sure the hose is secure. Or
(2) the Natural Gas outlet. The NG
hose comes equipped with a quick
connect male located at the end of the
hose and female quick connect
coupler. (The female quick connect
coupler must be connected to your
Natural Gas outlet prior to use. Use a
wrench and pipe dope to promote a
safe seal.) Insert the male end of the
quick connect into the female coupler
by pulling back on the outside ring on
the female end of the quick connect,
inserting the quick connect male end
of the hose into it and releasing the
ring. (The NG hose does not have an
additional regulator on it)
7. Open the valve on the propane tank
or natural gas outlet.
8. The priming button is located on the
backside of the low pressure
regulator. Purge the fuel line of air by
gently pressing the primer button for a
few seconds.
9. The starter key hole is located on
the control box located on the front
right side of the engine. Insert the key
and turn it to the START position and
hold until engine starts. (clockwise)
10. When the engine starts, release
key, allowing it to return to the ON
position, which is the middle position.
NOTE: Do not crank the engine
continuously for more than 30 seconds
at a time. If the engine does not start,
allow for a 3 minute cool down period
between starting attempts. Failure to
follow these guidelines can damage the
starter motor.
If the starter does not turn the engine
over, shut off the starter immediately.
Do not make further attempts to
start the engine until the condition
is corrected. Do not jump start using
another battery.
10. Allow unit to run two (2) minutes to
warm-up before plugging a cord into
the electrical outlets.
4