18
RTM-ATCA-F140 Series Installation and Use (6806800M97M)
Safety Notes
Safety Notes
System Damage
WARNING: The intra-building port (s) of the equipment or subassembly is suitable for
connection to intra-building or unexposed wiring or cabling only. The intra-building port (s)
of the equipment or subassembly MUST NOT be metallically connected to interfaces that
connect to the outside plant (OSP) or its wiring. These interfaces are designed for use as
intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089) and require
isolation from the exposed OSP cabling. The addition of primary protectors is not sufficient
protection in order to connect these interfaces metallically to OSP wiring.
The intra-building port(s) of the equipment or subassembly must use shielded intra-building
cabling/wiring that is grounded at both ends.
Operation
Make sure that the display devices that are permanently connected to the VGA interface
provide a fire enclosure according to the IEC/EN/UL/CSA 62368-1 and 60950-1
requirements.
All other devices that are only connected to the VGA interface for service purposes need
supervision during operation and must be disconnected after maintenance.
Product Damage - Product Surface
High humidity and condensation on the product surface causes short circuits.
Do not operate the product outside the specified environmental limits. Make sure the
product is completely dry and there is no moisture on any surface before applying power.
Overheating and Product Damage
When operating the product, make sure that forced air cooling is available in the shelf or
enclosure.
Operating the product without forced air cooling may lead to overheating and product
damage.
When operating the product in areas of electromagnetic radiation, secure the product in the
system using the front panel screws. Make sure the product is fully shielded by the
enclosure.
Data Corruption
If power to the unit is removed while a firmware update is in progress to the product's flash
memory, the changes will not be saved or the flash memory may be corrupted. In such
case, the product is likely to remain in a non-operable state and will require reconditioning
by qualified repair services.
Содержание RTM-ATCA-F140 Series
Страница 1: ...RTM ATCA F140 Series Installation and Use P N 6806800M97M December 2020...
Страница 6: ...6 RTM ATCA F140 Series Installation and Use 6806800M97M Table of Contents...
Страница 8: ...8 RTM ATCA F140 Series Installation and Use 6806800M97M Table of Contents...
Страница 10: ...List of Tables 10 RTM ATCA F140 Series Installation and Use 6806800M97M...
Страница 22: ...22 RTM ATCA F140 Series Installation and Use 6806800M97M Safety Notes Safety Notes...
Страница 72: ...72 RTM ATCA F140 Series Installation and Use 6806800M97M Functional Description Functional Description...
Страница 80: ...80 RTM ATCA F140 Series Installation and Use 6806800M97M Related Documentation Related Documentation...
Страница 81: ...1...