50
ATCA-F140 Series Installation and Use (6806800M67S)
Hardware Preparation and Installation
Hardware Preparation and Installation
2.3.2
Thermal Requirements
In order for the ATCA-F140 to cool properly when the operating temperature is at the
maximum (55
°
C), the chassis must meet or exceed PICMG 3.7 R1 Class B.3 ATCA
Chassis Specification. PICMG 3.7 R1 Class B.4 compliance is preferred.
Contact your SMART Embedded Computing sales representative for current information
on the detailed thermal information including airflow and resistance of the blade.
Vibration
1g from 5 to 200Hz and back to 5Hz at
a rate of 0.25 octave/minute
(according to Telcordia GR-63-core)
5-20Hz at 0.01 g
2
/Hz (according to
Telcordia GR-63-core and ETSI EN 300
019-2-2)
20-200Hz at -3dB/octave Hz (according
to Telcordia GR-63-core and ETSI EN
300 019-2-2)
Random 5-20Hz at 1m
2
/s
3
Random 20-200Hz at 3m
2
/s
3
Shock
Half-sine, 11ms at 30m/s
2
Blade level packaging
Half-sine, 6ms at 180m/s
2
Free Fall
NA
1.2 m/ packaged (according to ETSI 300
019-2-2)
100 mm unpackaged (according to
Telcordia GR-63-core)
Table 2-1
Environmental Requirements (continued)
Requirement Operating
Non-Operating
System Overheating - Cooling Vents
Improper cooling can lead to system damage and can void the manufacturer's
warranty.
To ensure proper cooling and undisturbed airflow through the system, do not
obstruct the ventilation openings of the system. Make sure that the fresh air supply
is not mixed with hot exhaust from other devices.
Personal Injury
During operation, hot surfaces may be present on the heat sinks and the
components of the product.
To prevent injury from hot surface, do not touch any of the exposed components or
heatsinks on the product when handing. Use the handle and face plate, where
applicable, or the board edge when removing the product from the enclosure.
Содержание ATCA-F140 Series
Страница 1: ...ATCA F140 Series Installation and Use P N 6806800M67S September 2019...
Страница 10: ...List of Figures 10 ATCA F140 Series Installation and Use 6806800M67S...
Страница 26: ...26 ATCA F140 Series Installation and Use 6806800M67S Safety Notes Safety Notes...
Страница 90: ...90 ATCA F140 Series Installation and Use 6806800M67S Controls LEDs and Connectors Controls LEDs and Connectors...
Страница 130: ...130 ATCA F140 Series Installation and Use 6806800M67S ATCA F140 TCLK3 Information ATCA F140 TCLK3 Information...
Страница 137: ...1...