3.Setting up the machine
3.1 Filling the main tank for the first time
Please follow these simple steps:
1. Use a plastic container to prepare the electrolyte solution first outside the machine.
Be sure to wear goggles
and rubber gloves for security reasons;
2. The electrolyte concentration to use is around 15 grs/liter of water. Add the full package (75 grs) provided
with the machine to 5 liters of water. You can use any type of water but try to avoid water with bad quality or
too many salts (iron or calcium). Tap water will work fine;
3. Connect the battery clamps of the power cable to the terminals of the battery in your car. The lateral fan
and a red light, buzzing and blinking, (Minimum Level) will be turned ON;
4. Open the water tank lid and pure gently the mixture inside the water tank avoiding any spell. As the water
level raises in the tank the red buzzing light will be turned OFF;
5. Continue adding the electrolyte solution until the green steady light is turned ON. When this light appears
please stop adding electrolyte solution;
6. Close the water tank lid making sure it is well tight.
3.2 Refilling the main tank
As you use the machine the water level inside the tank will start to descend. First the green will turn OFF. After
around 50 hours of work the red light will start to buzz and blink. It´s time to refill the machine again with
electrolyte solution
For refilling please follow these simple steps:
1. Use a plastic container to prepare the electrolyte solution first outside the machine.
Be sure to wear goggles
and rubber gloves for security reasons;
2. The electrolyte concentration to use is around 15 grs/liter of water. Add around 75 grs of Potassium
Hydroxide 90% pure to 5 liters of good quality water.
4. Open the water tank lid and pour gently the mixture inside the water tank avoiding any spell. As the water
level raises in the tank the red buzzing light will be turned OFF once again;
5. Continue adding the electrolyte solution until the green steady light is turned ON. When this light appears
please stop adding electrolyte solution;